York DGAHO77BBSA, DGPHO56ABTA La, Caution, 035-16328-Ray002C0902, Installation Of The Furnace

Models: DGPA056ABTA DGAAO77BDTA DGAHO77BBSA DGPA070ABTA DGPA090ABTA DGAA07OBDTA DGPH09OABTA DGAH056BBSA DGPA077ABTA DGPH077ABTA DGAA056BDTA DGAAO9OBDTA DGPHO70ABTA DGPHO56ABTA

1 28
Download 28 pages 26.06 Kb
Page 11
Image 11
035-16328-Ray002C(0902).

035-16328-Ray002C(0902).

LA, CAUTION]

FURNACE SEATED AGAINST THE LOCATOR BRACKET

\ SECUREFURNACE TO FLOOR WITH TWO NAILS OR SCREWS.

The inner flue pipe must be present.

It is mandatory that the combustion air pipe and flue pipe assembly be fully engaged. The com-

bustion air pipe MUST be securely fastened to the furnace with a sheet metal screw in the hole

provided.

Use a 1/2" blunt or sharp end sheet metal screw to fasten roof jack combustionair pipe to furnace combustion air colla_ Screw hole is provided in the pipe and collar Excessively long screws may extend to flue pipe and puncture it. Screws are not to exceed 1 1/2"in length.

 

NOTE: Combustion air tube and flue pipe are part of the

FIGURE 13 : Installation of Furnace

same assembly. Only the combustion air tube need be fas-

 

tened to the furnace.

INSTALLATION OF THE FURNACE

Remove the front panels and set the fumaca onto the duct connector. Slide it back until the rear of the unit engages the Iocator bracket.

2.Secure the front of the furnace with two screws at the mounting holes provided.

3.Secure the top of the furnace to a structural member using screw through the strap at the back of the furnace. Strap may be moved to any of the holes located along the top back of the furnace. Installer may provide an

equivalent method, such as screws through the casing side.

1.Check to be certain that the flue pipe and combustion air tube are present.

2.Pull the telescoping flue tube and combustion air tube assembly down from the roof jack. Slide the flue tube/ combustion air tube assembly down firmly over the fur- nace flue outlet and combustion air cellar. Insure that the back, side and front of combustion air tube collar is fully

engaged and is in contact with gasket, Fasten the com- bustion air tube to the furnace combustion air collar

usinga 1/2 inchsheet metal screw. (Screw hole provided in combustionair tube and fumaca combustionair collar.

See Figure 14.

COMBUSTION

SECURE STRAP

TO WALL_

It is mandatory that the combustion air and flue tube assembly be fully engaged at back sides and front, and combustion air tube securely fastened to the fumace with a sheet metal screw in the screw hole provided,

COMBUSTION

FRONT OF

 

FURNACE

#8 OR #10 SCREW RECOMMENDED

 

FIGURE 14 : Connecting Roof JAck to Furnace

Unitary Products Group

11

Page 11
Image 11
York DGAHO77BBSA, DGPHO56ABTA, DGPHO70ABTA, DGAAO9OBDTA La, Caution, 035-16328-Ray002C0902, Installation Of The Furnace