York DGAAO9OBDTA 035-16328-Rev002C0902, Furnace Specifications, 45,006, NATURALGASI 66,090I

Models: DGPA056ABTA DGAAO77BDTA DGAHO77BBSA DGPA070ABTA DGPA090ABTA DGAA07OBDTA DGPH09OABTA DGAH056BBSA DGPA077ABTA DGPH077ABTA DGAA056BDTA DGAAO9OBDTA DGPHO70ABTA DGPHO56ABTA

1 28
Download 28 pages 26.06 Kb
Page 2
Image 2
035-16328-Rev002C(0902).

035-16328-Rev002C(0902).

FURNACE SPECIFICATIONS

DGAA --AUTOMATIC IGNITION -- WITH BUILT-IN COIL CABINET --4 TON - AIC READY

MODEL NO,

 

Factor'/Equipped for use with

Input/BTUH

OutputJBTUH

DGAA056BDTA

 

NATURAL GAS

56,000

45,000

DGAA07OBDTA

 

NATURAL GAS

70,000

56,000

DGAAO77BDTA

 

NATURAL GAS

77,000

62,000

DGAAO9OBDTA

 

NATURAL GAS

90,000

72,000

DGPA --STANDING PILOT -- WITH BUILT-IN COIL CABINET --3 TON - AIC READY

 

DGPA056ABTA

 

NATURAL GAS

56,000

45,000

DGPA070ABTA

 

NATURAL GAS

70,000

56,000

DGPA077ABTA

 

NATURAL GAS

77,000

62,000

DGPA090ABTA

 

NATURAL GAS

90,000

72,000

DGPH --STANDING PILOT -- WITH BUILT-IN COIL CABINET --3 TON - NO AIC CONTROLS

DGPHO56ABTA

 

NATURALGAS

56,000

45,000

DGPHO70ABTA

 

NATURALGAS

79,000

66,000

DGPH077ABTA

 

NATURALGAS

77,005

62,000

DGPH09OABTA

 

NATURALGAS

90,000

72,000

 

DGAH --AUTOMATIC IGNITION --HEATING ONLY --NO COIL CABINET

45,006

DGAH056BBSA

I

NATURALGASI 66,090I

 

 

 

 

DGAHO77BBSA

 

NATURAL GAS

77,000

62,000

 

 

 

 

ELECTRICAL

SPECIFICATIONS

 

Electdcal Power Supply

115 Volts - 60 Hz - 1 Phase

 

Breaker or Fuse

15 Arnp

 

 

 

 

 

 

Thermostat

Circuit

24 Volt - 60 Hz - 40 VA

Nominal Anticipator Setting

.50

 

 

Gas Valve

Inlet

1/2" NFPT

 

 

 

 

24-314"

 

 

 

 

19.1/2 °

 

24-314"

19-1/2"

76"

5g=1/2"

DGAHSeries

DGPH, DGPA & DGAA Series

FIGURE 1 : Furnace Dimensions