035-16328-Rev002C(0902).
FURNACE SPECIFICATIONS
DGAA
MODEL NO, |
| Factor'/Equipped for use with | Input/BTUH | OutputJBTUH |
DGAA056BDTA |
| NATURAL GAS | 56,000 | 45,000 |
DGAA07OBDTA |
| NATURAL GAS | 70,000 | 56,000 |
DGAAO77BDTA |
| NATURAL GAS | 77,000 | 62,000 |
DGAAO9OBDTA |
| NATURAL GAS | 90,000 | 72,000 |
DGPA |
| |||
DGPA056ABTA |
| NATURAL GAS | 56,000 | 45,000 |
DGPA070ABTA |
| NATURAL GAS | 70,000 | 56,000 |
DGPA077ABTA |
| NATURAL GAS | 77,000 | 62,000 |
DGPA090ABTA |
| NATURAL GAS | 90,000 | 72,000 |
DGPH | ||||
DGPHO56ABTA |
| NATURALGAS | 56,000 | 45,000 |
DGPHO70ABTA |
| NATURALGAS | 79,000 | 66,000 |
DGPH077ABTA |
| NATURALGAS | 77,005 | 62,000 |
DGPH09OABTA |
| NATURALGAS | 90,000 | 72,000 |
| DGAH | 45,006 | ||
DGAH056BBSA | I | NATURALGASI 66,090I | ||
|
|
|
| |
DGAHO77BBSA |
| NATURAL GAS | 77,000 | 62,000 |
|
| |||
|
| ELECTRICAL | SPECIFICATIONS |
|
Electdcal Power Supply | 115 Volts - 60 Hz - 1 Phase | |||
| Breaker or Fuse | 15 Arnp |
| |
|
|
|
| |
| Thermostat | Circuit | 24 Volt - 60 Hz - 40 VA | |
Nominal Anticipator Setting | .50 |
| ||
| Gas Valve | Inlet | 1/2" NFPT |
|
|
|
|
| |
|
|
| 19.1/2 ° |
|
76"
5g=1/2"
DGAHSeries | DGPH, DGPA & DGAA Series |
FIGURE 1 : Furnace Dimensions
2 | Unitary Products Group |