York H4DH018 THRU 060 warranty 036-21020-003Rev. C, Procedures, Unitary Products Group

Models: H4DH018 THRU 060

1 20
Download 20 pages 49.34 Kb
Page 3
Image 3
Procedures:

036-21020-003 Rev. C (0203)

Additional R-22 Charge / Orifice Size for Various Matched Systems

ADDITIONAL R-22 CHARGE / ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS

Outdoor Unit

 

H4DH018S06

H4DH024S06

H4DH030S06

H4DH036S06

H4DH042S06

H4DH048S06

H4DH060S06

Unit Orifice (s) 1

 

55, 57

61, 63

69, 71

75, 78

75, 78

87, 90

99

Factory R-22 Charge, lbs-oz

4 - 14

5 - 1

5 - 4

5 - 15

6 - 12

8 - 10

7 - 13

 

 

 

 

 

 

 

 

 

Indoor Coil

Coil Orifice 2

 

 

System Orifice = Additional Charge, Oz

 

 

G2FD024(S,H)14,17

61

57 + 6

63 + 2

G2FD030(S,H)17

65

57 + 8

63 + 4

69 + 0

7013 + 0

 

 

 

 

 

 

 

 

G2FD035(S,H)14

65

57 + 8

63 + 4

69 + 3

75 + 0

G2FD036(S,H)17,21

75

 

63 + 8

69 + 3

75 + 10

G2FD042(S,H)21

78

75 + 13

75 + 5

G2FD046(S,H)17

78

71 + 6

75 + 13

75 + 5

87+ 0

G2FD048(S,H)21,24

84

71 + 7

75 + 24/7023 + 24

75 + 20

87 + 8

G2FD060(S,H)24

90

 

78 + 15

90 + 10/7033 + 10

99 + 13/7033 + 13

G2FD061(H)24

90

90 + 21

7033 + 5

G1HD024

59

55 + 7

63 + 3

G1HD036

69

63 + 10

69 + 3

75 + 18

G1HD048

84

78 + 22

75 + 14

87 + 1

G1HD060

96

90 + 5

99 + 9

G1UA024S14,17

59

57 + 4

61 + 0

GIFA024S14,17

59

57 + 4

61 + 0

G1UA030S14

65

57 + 6

63 + 2

7013 + 0

GIFA030S14

65

57 + 6

63 + 2

7013 + 0

G1UA036S14,17,21

73

55 + 8

63 + 2

69 + 3

75 + 0

GIFA036S14,17,21

73

55 + 8

63 + 2

69 + 3

75 + 0

G1UA048S17

84

71 + 6

78 + 20

75 + 15

87 + 7

GIFA048S17

84

71 + 6

78 + 20

75 + 15

87 + 7

G1UA048S21

84

71 + 6

78 + 20/7023 + 20

75 + 19

87 + 7

GIFA048S21

84

71 + 6

78 + 20/7023 + 20

75 + 19

87 + 7

G1UA060S21,24

90

78 + 16

90 + 10/7033 + 15

99 + 9

GIFA060S21,24

90

78 + 16

90 + 10/7033 + 15

99 + 9

G1NA030S17H

57

57 + 6

G1NA030S17K

63

65 + 6

69 + 0

G1NA036S17J

67

75 + 6

G1NA048S21D

78

7023 + 15

75 + 12

87 + 3

F2RC/F2FC024

61

55 + 4

63 + 0

F2RC/F2FC030

65

63 + 4

69 + 0

F2RC/F2FC036

73

73 + 3

78 + 12

F2RP/F2FP018

59

55 + 0

F2RP/F2FP024

61

55 + 6

61 + 0

F2RP/F2FP030

65

63 + 4

69 + 0/7013 + 0

F2RP/F2FP036

75

71 + 3

78 + 12

F2FP040

63

7013 + 14

71 + 6

F2RP/F2FP042

78

78 + 14

75 + 8

F2FP045

78

7023 + 28

78 + 20

F2RP/F2FP048

84

78 + 23

75 + 16

87 + 7

F2RP/F2FP060

90

90 + 10

99 + 13/7033 + 13

F2FV060

90

90 + 10

7033 + 0

Footnotes:

 

 

 

 

 

 

 

 

1.These orifices are packed in the customer packet of each outdoor unit.

2.These orifices are factory mounted in the flow control device of each indoor coil.

3.A TXV Kit must be used with these units to obtain system performance (701,702,703 indicates 1TV07---Series).

Procedures:

1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of interconnecting line tubing. 2.Verify the orifice size and additional charge required for specific evaporator coil in the system using the above table.

3.Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.

4.Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.

5.If the orifice in the evaporator was changed, verify the evaporator nameplate has been marked with the correct orifice size. 6.Due to serial compressor, hard start components are not required when using coils with TXV or solenoid valve kits.