York H4DH018 THRU 060 warranty Cooling Performance Data, Air Conditioner Model No

Models: H4DH018 THRU 060

1 20
Download 20 pages 49.34 Kb
Page 13
Image 13
Manual background

 

 

 

 

 

 

 

 

 

 

 

 

 

036-21020-003 Rev. C (0203)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING PERFORMANCE DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR CONDITIONER MODEL NO.

 

H4DH024S06

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

 

 

G1FA024S14,17

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

 

800

 

 

 

 

850

 

 

 

 

900

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING AIR

ID DB

 

85

80

 

75

70

85

80

 

75

70

 

85

80

 

75

70

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB

 

72

67

 

62

57

72

67

 

62

57

 

72

67

 

62

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

 

27.8

25.4

 

23.2

21.1

27.9

25.6

 

23.4

21.4

 

28.1

25.8

 

23.5

21.6

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

 

17.9

18.0

 

18.2

18.3

18.5

18.5

 

18.7

19.0

 

19.0

19.1

 

19.2

19.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

 

1.66

1.64

 

1.63

1.61

1.68

1.66

 

1.65

1.64

 

1.70

1.68

 

1.67

1.66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

 

26.6

24.4

 

22.2

20.3

26.8

24.6

 

22.4

20.5

 

26.9

24.7

 

22.5

20.7

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

 

17.5

17.6

 

17.8

17.9

18.1

18.1

 

18.3

18.5

 

18.5

18.6

 

18.8

18.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

 

1.79

1.78

 

1.76

1.75

1.81

1.80

 

1.78

1.77

 

1.84

1.82

 

1.80

1.79

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

 

25.4

23.3

 

21.1

19.4

25.5

23.4

 

21.3

19.6

 

25.7

23.5

 

21.5

19.7

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

 

17.1

17.1

 

17.3

17.4

17.6

17.6

 

17.8

17.9

 

18.1

18.1

 

18.4

18.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

 

2.00

1.98

 

1.96

0.39

2.02

2.00

 

1.98

1.97

 

2.04

2.02

 

0.47

1.99

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

 

24.1

22.1

 

20.1

18.4

24.2

22.2

 

20.2

18.6

 

24.4

22.3

 

20.5

18.7

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

 

16.6

16.6

 

16.8

16.9

17.1

17.1

 

17.3

17.4

 

17.6

17.6

 

18.0

17.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

 

2.23

2.21

 

2.19

2.17

2.26

2.23

 

2.21

2.19

 

2.28

2.26

 

2.23

2.21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

 

22.8

20.9

 

19.0

17.4

22.9

21.0

 

19.2

17.5

 

23.0

21.1

 

19.4

17.7

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

 

16.1

16.1

 

16.4

16.3

16.6

16.6

 

17.0

16.8

 

17.1

17.1

 

17.4

17.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

 

2.50

2.48

 

2.45

2.42

2.52

2.50

 

2.47

2.45

 

2.54

2.52

 

2.49

2.47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

 

21.5

19.7

 

17.9

16.4

21.6

19.8

 

18.2

16.4

 

21.6

19.9

 

18.3

16.7

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

 

15.6

15.6

 

16.0

15.7

16.1

16.1

 

16.7

16.2

 

16.6

16.6

 

16.8

16.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

 

2.77

2.75

 

2.71

2.67

2.78

2.77

 

2.73

2.71

 

2.80

2.78

 

2.75

2.73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

Air Handler

Coil

T.C.

S.C.

KW

N1AHB08

G2FD024(S,H)17

1.00

1.00

0.99

N1AHB08

G2FD030(S,H)17

1.00

1.00

0.99

N1VSB12

G2FD024(S,H)17

1.04

1.04

0.93

N1VSB12

G2FD036(S,H)17

1.05

1.05

0.94

F2RC/FC024

 

0.98

0.98

0.98

F2FP/FP024

 

1.03

1.03

1.02

F2RC/FC030

 

1.00

1.00

0.99

F2RP/FP030

 

1.04

1.04

1.04

F2FP040

 

1.06

1.06

1.01

 

G1FA036S14

1.03

1.03

1.03

 

G1FA036S17,21

1.03

1.03

1.02

 

G1HD024

1.00

1.00

1.01

 

G1HD036

1.03

1.03

1.02

 

G1NA030S17

1.03

1.03

1.00

 

G1UA024S14,17

1.00

1.00

1.00

 

G2FD036(S,H)17

1.03

1.03

1.02

 

G1UA030S14

1.00

1.00

0.99

 

G1UA036S14

1.03

1.03

1.03

 

G1UA036S17,21

1.03

1.03

1.02

 

G2FD030(S,H)17

1.00

1.00

0.99

 

G2FD024(S,H)14,17

1.00

1.00

0.99

 

G2FD035(S,H)14

1.00

1.00

1.00

 

G1FA030S14

1.00

1.00

0.99

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

P1DUA12V

G1FA024S14

1.03

1.03

0.93

 

 

 

 

 

P1DUA12V

G1FA030S14

1.03

1.03

0.92

 

 

 

 

 

P1DUA12V

G1FA036S14

1.05

1.05

0.95

 

 

 

 

 

P1DUA12V

G1HD024

1.03

1.03

0.94

 

 

 

 

 

P1DUA12V

G1HD036

1.05

1.05

0.95

 

 

 

 

 

P1DUA12V

G1UA024S14

1.03

1.03

0.93

 

 

 

 

 

P1DUA12V

G1UA030S14

1.03

1.03

0.92

 

 

 

 

 

P1DUA12V

G1UA036S14

1.05

1.05

0.95

 

 

 

 

 

P1DUA12V

G2FD024(S,H)14

1.03

1.03

0.92

 

 

 

 

 

P1XDB12V

G2FD024(S,H)17

1.02

1.02

0.93

 

 

 

 

 

P1XUB12V

G1FA024S17

1.03

1.03

0.93

 

 

 

 

 

P1XUB12V

G1FA036S17

1.05

1.05

0.95

 

 

 

 

 

P1XUB12V

G1UA024S17

1.03

1.03

0.93

 

 

 

 

 

P1XUB12V

G1UA036S17

1.05

1.05

0.95

 

 

 

 

 

P1XUB12V

G2FD024(S,H)17

1.03

1.03

0.92

 

 

 

 

 

P1XUB12V

G2FD030(S,H)17

1.05

1.05

0.95

 

 

 

 

 

P1XUB12V

G2FD036(S,H)17

1.05

1.05

0.95

 

 

 

 

 

Unitary Products Group

13

Page 13
Image 13
York H4DH018 THRU 060 warranty Cooling Performance Data, Air Conditioner Model No