| A | |
• SINGLE INPUT ELECTRONIC ENTHALPY | ||
bracket installed in the Blower Access compartment which | ||
ECONOMIZERS - Includes a | may accommodate other vendor’s drives depending on | |
assembly with fully modulating | their size. In order to utilize the unit’s mounting bracket, | |
actuator capable of introducing up to 100% outdoor air | the maximum recommended drive dimensions are as fol- | |
with nominal 1% leakage type dampers. | lows: | |
The enthalpy system contains one sensor that monitors | For | |
the outdoor air and determines when the air is cool | ||
For 7.5 thru | ||
enough and dry enough to provide free cooling. | ||
The rainhood is painted to match the basic unit and must | If the | |
be | space, then it will have to be mounted within a | |
• POWER EXHAUST - Our single economizer options are | enclosure for outside installation or inside the building on | |
a perpendicular wall not subjected to excessive tempera- | ||
available with power exhaust. Whenever the outdoor air | ||
ture, vibration, humidity, dust, corrosive gas, explosive | ||
intake dampers are opened for free cooling, the exhaust | ||
gas, etc. | ||
fan will be energized to prevent the conditioned space | ||
| ||
from being | A terminal block located in the control box is provided for | |
The exhaust fan, motor and controls are installed and | field connection of the VFD controls. | |
wired at the factory. The rain hood must be assembled | • HOT GAS BYPASS - To allow for low cooling load opera- | |
and installed in the field. | ||
tion, a | ||
• MOTORIZED OUTDOOR AIR INTAKE DAMPER - | ||
valve installed on the system #1 discharge line is used to | ||
Includes a | ||
divert high temperature, high pressure refrigerant around | ||
position, spring return motor actuator which opens to a | ||
the TXV in order to maintain a desired minimum evaporator | ||
pressure. HGBP is standard on all units with VAV and | ||
operating and will drive fully closed when the blower unit | ||
optional with CV units. | ||
shuts down. | ||
• FILTER OPTIONS - Standard units are shipped with 2” | ||
The rain hood is painted to match the basic unit and must | ||
be field assembled before installing. | ||
filters are offered as a factory installed option. | ||
• PHENOLIC COATED EVAPORATOR, REHEAT, AND | ||
• CONVENIENCE OUTLET - This 110 volt outlet can be | ||
CONDENSER COILS - Special coating process that | ||
“powered” by the unit with a stepdown transformer or you | ||
utilizes Technicoat | ||
may order the unit with a | ||
total immersion of the complete coil for maximum | ||
outlet that can be wired in the field. | ||
protection. | ||
• DISCONNECT SWITCH - For gas heat units and cooling | ||
• ELECTRIC HEATERS wired for single point power | ||
units with electric heat, a HACR breaker sized to the unit | ||
supply. These nickel chromium heater elements are | ||
is provided. For cooling only units, a switch sized to the | ||
provided with limit and automatic reset capability to | ||
largest electric heat available for the particular unit is | ||
prevent operation at excessive temperatures. | ||
provided. Factory installed option only. | ||
• VARIABLE AIR VOLUME (VAV) - A | ||
• DOUBLE WALL CONSTRUCTION - Optional double wall | ||
variable frequency drive (VFD), mounted in the Blower | ||
construction is available to provide smooth inner surfaces | ||
Access compartment, is used to control the speed of the | ||
for easy and effective cleaning to reduce risk of dirt and | ||
indoor blower motor in order to maintain a constant static | ||
bacterial accumulation. Fiberglass insulation is | ||
pressure in the supply duct. A pressure transducer and | ||
sandwiched between heavy gauge steel sheets to form a | ||
VAV control board are mounted inside the control box. | ||
durable, rigid casing to withstand higher working | ||
The drive comes completely wired and | ||
pressures and impact forces. The | ||
from the factory. | ||
provides excellent acoustic and thermal insulation and | ||
An optional, | ||
eliminates erosion of insulation material and | ||
able with | contamination of the air stream. | |
Motor Access compartment. The switch can be used to | • BAS - Building Automation System Controls | |
either route power to the VFD for modulating control of the | ||
(available on | ||
blower motor, to bypass the drive and operate the motor | ||
Simplicity® | ||
at full speed, or to power the drive (and not the motor) for | ||
diagnostic purposes. | Simplicity® | |
It includes a supply air sensor, a return air sensor, and an | ||
Due to space limitations, VAV is not available with any of | ||
outside air sensor. There are provisions for a field installed | ||
the | dirty filter indicator switch, an | |
available with | side Air Humidity sensor, a Return Air Humidity sensor, an | |
provided in the control box for field wiring of the customer- | Inside IAQ sensor, and an Outside Air IAQ sensor. Con- | |
installed BAS. |
|
8 | Unitary Products Group |