York YCJD18 THRU 60 warranty YTG-A-0612, Johnson Controls Unitary Products

Models: YCJD18 THRU 60

1 28
Download 28 pages 61.07 Kb
Page 7
Image 7
Manual background

840569-YTG-A-0612

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

AIR HANDLER

 

COIL

 

 

 

COOLING

 

 

MODEL

MODEL

WIDTH

 

MODEL1

RATED

 

NET MBH

SEER

EER

 

CFM

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

13 SEER AC WITH AIR HANDLERS

 

 

 

 

 

AHE48D

24.5

 

1600

 

47.0

34.6

13.75

11.50

 

AHP48

24.5

 

1675

 

48.0

34.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

AHP60

24.5

 

1600

 

48.0

35.0

13.50

11.00

 

 

 

 

 

 

 

 

 

 

 

 

AHR48D

24.5

 

1610

 

48.0

34.6

13.00

11.00

 

AHX48

24.5

 

1660

 

48.0

35.4

13.50

11.50

 

AV*48

24.5

 

1625

 

48.0

35.0

13.50

12.00

 

 

 

 

 

 

 

 

 

 

 

 

AV*60

24.5

 

1560

 

48.0

35.0

13.50

12.00

 

 

 

 

 

 

 

 

 

 

 

 

F4FV060

24.5

 

1600

 

48.0

34.6

14.00

11.50

 

 

 

 

 

 

 

 

 

 

 

YCJD48S41S1(H)(E)

F5FP048

24.5

 

1600

 

48.0

34.4

13.00

11.00

F5FP060

24.5

 

1600

 

48.0

34.4

13.00

11.00

 

 

 

 

F6FP048

24.5

 

1625

 

47.0

34.8

13.00

11.30

 

 

 

 

 

 

 

 

 

 

 

 

MV16C

21.0

 

FC/MC48C

1600

 

48.0

35.0

13.50

12.00

 

 

 

 

 

 

 

 

 

 

 

 

MV16C

21.0

 

FC60C

1625

 

47.5

34.6

13.50

11.50

 

 

 

 

 

 

 

 

 

 

 

 

MV20D

24.5

 

FC/MC48D

1600

 

48.0

35.0

13.50

12.00

 

MV20D

24.5

 

FC/MC60D

1600

 

48.0

35.0

13.50

12.00

 

MX16C

21.0

 

FC/MC48C

1685

 

48.5

35.6

13.75

11.50

 

 

 

 

 

 

 

 

 

 

 

 

MX20D

24.5

 

FC/MC48D

1525

 

48.0

34.2

14.00

11.75

 

 

 

 

 

 

 

 

 

 

 

 

MX20D

24.5

 

FC/MC60D

1585

 

48.5

34.6

14.00

12.00

 

AHE60D

24.5

 

1835

 

58.5

39.8

13.50

11.50

 

AHP60

24.5

 

1850

 

57.0

38.5

13.00

11.00

 

AHR60D

24.5

 

1870

 

57.0

38.5

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

AHX60

24.5

 

1905

 

58.5

40.0

13.50

11.50

 

 

 

 

 

 

 

 

 

 

 

 

AV*60

24.5

 

1730

 

58.0

39.0

13.50

11.00

 

 

 

 

 

 

 

 

 

 

 

 

F4FV060

24.5

 

1780

 

57.0

38.5

13.50

11.00

YCJD60S41S1(E)

F5FP060

24.5

 

1900

 

57.0

38.5

13.00

11.00

F6FP060

24.5

 

1710

 

57.5

39.0

13.50

11.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MV20D

24.5

 

FC/MC60D

1800

 

57.0

38.5

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

MV20D

24.5

 

FC/MC62D

1800

 

57.0

38.5

13.00

11.00

 

MV20D

24.5

 

FC64D

1855

 

57.0

39.0

13.75

11.50

 

MX20D

24.5

 

FC/MC60D

1780

 

57.5

38.8

13.75

11.50

 

MX20D

24.5

 

FC/MC62D

1795

 

58.0

38.8

14.00

11.75

 

 

 

 

 

 

 

 

 

 

 

 

MX20D

24.5

 

FC64D

1795

 

58.5

39.8

14.50

12.00

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240. Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.

SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

= Not applicable.

MA Modular Air Handlers use Coil Only Ratings.

Johnson Controls Unitary Products

7

Page 7
Image 7