York YCJD18 THRU 60 warranty YTG-A-0612

Models: YCJD18 THRU 60

1 28
Download 28 pages 61.07 Kb
Page 8
Image 8

840569-YTG-A-0612

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)

 

COIL

CFM RANGE

 

 

COOLING

 

 

UNIT MODEL

 

 

RATED

NET MBH

SEER 1

 

MODEL

WIDTH

(MIN.-MAX.)

EER

 

CFM

 

 

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13 SEER AC COIL ONLY RATINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

YCJD18S41S1(H)(E)

FC/MC/PC18

14.5,17.5

450-750

600

17.5

12.9

13.00

11.00

 

 

 

 

 

 

 

 

UC18

14.5,17.5

450-750

600

17.5

12.9

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

FC/MC/PC32

14.5

600-1000

800

24.0

16.7

13.00

11.00

 

 

 

 

 

 

 

 

 

 

FC/MC/PC35

17.5,21.0

600-1000

800

24.0

16.7

13.00

11.00

 

 

 

 

 

 

 

 

 

YCJD24S41S1(H)(E)

FC/MC/PC36

14.5,17.5,21.0

600-1000

800

24.0

16.7

13.00

11.00

 

 

 

 

 

 

 

 

FC/MC/PC37

14.5

600-1000

800

24.0

16.7

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

FC/MC/PC43

17.5,21.0

600-1000

800

24.0

16.7

13.00

11.00

 

 

 

 

 

 

 

 

 

 

UC36

14.5,17.5,21.0

600-1000

800

24.0

16.7

13.00

11.00

 

 

 

 

 

 

 

 

 

 

FC/MC/PC32

14.5

800-1200

1000

29.0

21.0

13.00

11.00

 

 

 

 

 

 

 

 

 

YCJD30S41S1(H)(E)

FC/MC/PC35

17.5,21.0

800-1200

1000

29.0

21.0

13.00

11.00

 

 

 

 

 

 

 

 

FC/MC/PC37

14.5

800-1200

1000

29.0

21.0

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

FC/MC/PC43

17.5,21.0

800-1200

1000

29.0

21.0

13.00

11.00

 

 

 

 

 

 

 

 

 

 

FC/MC/PC37

14.5

1000-1400

1200

35.0

24.8

13.00

11.00

 

 

 

 

 

 

 

 

 

YCJD36S41S1(H)(E)

FC/MC/PC43

17.5,21.0

1000-1400

1200

35.0

24.8

13.00

11.00

 

 

 

 

 

 

 

 

FC/MC/PC48

21.0,24.5

1000-1400

1200

35.0

24.8

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

UC48

21.0,24.5

1000-1400

1200

35.0

24.8

13.00

11.00

 

FC/MC/PC43

17.5,21.0

1200-1600

1400

41.5

29.8

13.00

11.00

 

FC/MC/PC48

21.0,24.5

1200-1600

1400

42.0

30.0

13.00

11.00

 

 

 

 

 

 

 

 

 

YCJD42S41S2(H)(E)

FC/MC/PC60

21.0,24.5

1200-1600

1400

41.5

29.6

13.00

11.00

 

 

 

 

 

 

 

 

FC/MC62

24.5

1200-1600

1400

42.0

30.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

FC64

24.5

1200-1600

1400

42.0

30.8

13.25

11.25

 

 

 

 

 

 

 

 

 

 

UC48

21.0,24.5

1200-1600

1400

42.0

30.0

13.00

11.00

 

FC/MC/PC48

21.0,24.5

1400-1800

1600

48.0

34.4

13.00

11.00

YCJD48S41S1(H)(E)

FC/MC/PC60

21.0,24.5

1400-1800

1600

48.0

34.4

13.00

11.00

 

 

 

 

 

 

 

 

UC48

21.0,24.5

1400-1800

1600

48.0

34.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

UC60

21.0,24.5

1400-1800

1600

48.0

34.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

FC/MC/PC60

21.0,24.5

1600-2000

1800

57.0

38.5

13.00

11.00

 

 

 

 

 

 

 

 

 

YCJD60S41S1(E)

FC/MC62

24.5

1600-2000

1800

57.0

38.5

13.00

11.00

 

 

 

 

 

 

 

 

FC64

24.5

1600-2000

1800

57.0

39.0

13.50

11.25

 

 

 

 

 

 

 

 

 

 

 

UC60

21.0,24.5

1600-2000

1800

57.0

38.5

13.00

11.00

 

 

 

 

 

 

 

 

 

1.Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one. MA Modular Air Handlers use Coil Only Ratings.

PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.

8

Johnson Controls Unitary Products

Page 8
Image 8
York YCJD18 THRU 60 warranty YTG-A-0612