York YHJD18 warranty Johnson Controls Unitary Products

Models: YHJD18

1 36
Download 36 pages 6.88 Kb
Page 13
Image 13

HEATING PERFORMANCE - Upflow, Downflow, and Horizontal Furnaces and Coils

UNIT

COIL1

 

 

 

ARI HEATING2

 

 

 

MODEL*

MODEL

 

47°F

 

 

 

 

17°F

 

HSPF

 

 

MBH

COP

KW

 

MBH

 

COP

KW

STD

 

FC/MC/PC/UC18

17.0

3.32

1.50

 

12.7

 

3.00

1.24

7.70

 

FC/MC/PC/UC24

17.0

3.44

1.45

 

10.4

 

2.60

1.17

7.70

YHJD18S41S1

HC18

17.0

3.32

1.50

 

12.7

 

3.00

1.24

7.70

 

HC30

17.0

3.38

1.47

 

10.4

 

2.60

1.17

7.70

 

HD24

16.6

3.16

1.54

 

12.8

 

3.00

1.25

7.70

 

FC/MC/PC32

23.2

3.40

2.00

 

12.6

 

2.24

1.65

7.70

 

FC/MC/PC35

23.2

3.40

2.00

 

12.6

 

2.24

1.65

7.70

YHJD24S41S1

HC30

23.0

3.40

1.98

 

12.6

 

2.24

1.65

7.70

 

HC36

23.2

3.40

2.00

 

12.6

 

2.24

1.65

7.70

 

HD36

23.2

3.40

2.00

 

12.6

 

2.24

1.65

7.70

 

FC/MC/PC37

28.2

3.40

2.43

 

16.6

 

2.32

2.10

7.70

YHJD30S41S1

FC/MC/PC43

28.2

3.40

2.43

 

16.6

 

2.32

2.10

7.70

HC42

28.2

3.40

2.43

 

16.6

 

2.32

2.10

7.70

 

 

 

 

HD48

28.2

3.60

2.30

 

16.6

 

2.32

2.10

7.70

 

FC/MC/PC37

35.0

3.40

3.02

 

21.2

 

2.36

2.63

8.00

 

FC/MC/PC43

35.0

3.42

3.00

 

21.2

 

2.36

2.63

8.00

YHJD36S41S1

FC/MC/PC48

35.0

3.42

3.00

 

21.4

 

2.36

2.66

8.00

 

HC42

35.0

3.42

3.00

 

21.2

 

2.36

2.63

8.00

 

HD48

35.0

3.40

3.02

 

20.0

 

2.16

2.71

8.00

 

FC/MC/PC60

41.0

3.66

3.28

 

27.8

 

2.56

3.18

8.00

YHJD42S41S1

 

 

 

 

 

 

 

 

 

 

HC60

41.0

3.66

3.28

 

27.8

 

2.56

3.18

8.00

 

 

 

 

 

 

 

 

 

 

 

 

HD60

41.0

3.14

3.83

 

27.6

 

2.26

3.58

8.00

 

 

 

 

 

 

 

 

 

 

 

 

FC/MC/PC48

50.5

3.32

4.46

 

30.8

 

2.24

4.03

8.00

 

 

 

 

 

 

 

 

 

 

 

 

FC/MC/PC60

51.0

3.50

4.27

 

30.6

 

2.34

3.83

8.00

YHJD48S41S1

 

 

 

 

 

 

 

 

 

 

HC60

51.0

3.50

4.27

 

30.6

 

2.34

3.83

8.00

 

 

 

 

 

 

 

 

 

 

 

 

HD60

50.0

2.98

4.92

 

30.6

 

2.06

4.35

8.00

 

 

 

 

 

 

 

 

 

 

 

 

MC62

50.5

3.38

4.38

 

30.6

 

2.28

3.93

8.00

 

 

 

 

 

 

 

 

 

 

 

YHJD60S41S1

MC62

56.5

3.48

4.76

 

35.4

 

2.42

4.29

8.00

 

 

 

 

 

 

 

 

 

 

 

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no

supplemental electric heat operation.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.

Johnson Controls Unitary Products

13

Page 13
Image 13
York YHJD18 warranty Johnson Controls Unitary Products