HEATING PERFORMANCE DATA

CONDENSING UNIT MODEL NO

YHJD42S41S1

 

 

 

 

 

 

 

EVAPORATOR COIL MODEL NO

FC/MC/PC/UC48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

ID CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING

ENTERING

 

1200

 

 

1400

 

 

1600

 

OUTDOOR UNIT

INDOOR COIL

 

 

 

 

 

 

 

 

 

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

 

 

 

 

 

 

 

 

 

 

 

 

60

48.7

3.5

4.1

48.7

3.5

4.1

48.7

3.4

4.2

60

 

 

 

 

 

 

 

 

 

 

70

47.8

3.8

3.6

48.6

3.8

3.7

49.5

3.8

3.8

 

 

 

 

 

 

 

 

 

 

 

 

80

46.8

4.2

3.3

48.6

4.2

3.4

50.3

4.1

3.6

 

 

 

 

 

 

 

 

 

 

 

 

60

42.5

3.3

3.8

42.9

3.3

3.8

43.3

3.2

3.9

47

 

 

 

 

 

 

 

 

 

 

70

42.3

3.6

3.4

42.7

3.6

3.5

43.1

3.6

3.6

 

 

 

 

 

 

 

 

 

 

 

 

80

42.0

3.9

3.1

42.4

3.9

3.2

42.9

3.9

3.3

 

 

 

 

 

 

 

 

 

 

 

 

60

40.1

3.2

3.7

40.5

3.2

3.7

40.8

3.2

3.8

40

 

 

 

 

 

 

 

 

 

 

70

39.1

3.5

3.3

39.6

3.5

3.3

40.0

3.5

3.4

 

 

 

 

 

 

 

 

 

 

 

 

80

38.2

3.8

2.9

38.7

3.8

3.0

39.2

3.8

3.0

 

 

 

 

 

 

 

 

 

 

 

 

60

33.5

3.8

2.6

33.8

3.7

2.7

34.1

3.7

2.7

30

 

 

 

 

 

 

 

 

 

 

70

34.8

3.4

3.0

34.5

3.4

3.0

34.1

3.4

2.9

 

 

 

 

 

 

 

 

 

 

 

 

80

36.2

3.1

3.4

35.1

3.1

3.3

34.1

3.1

3.2

 

 

 

 

 

 

 

 

 

 

 

 

60

27.8

3.6

2.2

28.4

3.6

2.3

29.1

3.6

2.4

17

 

 

 

 

 

 

 

 

 

 

70

28.3

3.3

2.5

28.8

3.3

2.5

29.2

3.3

2.6

 

 

 

 

 

 

 

 

 

 

 

 

80

28.8

3.0

2.8

29.1

3.0

2.8

29.4

3.0

2.8

 

 

 

 

 

 

 

 

 

 

 

 

60

26.3

3.6

2.1

26.9

3.6

2.2

27.6

3.6

2.2

10

 

 

 

 

 

 

 

 

 

 

70

25.6

3.3

2.3

26.8

3.3

2.4

28.0

3.3

2.5

 

 

 

 

 

 

 

 

 

 

 

 

80

24.8

3.0

2.4

26.6

3.0

2.6

28.4

3.0

2.8

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

Air Handlers

Coils

MBH

KW

COP

FC/MC/PC60

1.00

1.06

0.94

HC42

0.99

0.99

1.00

HC60

1.00

1.06

0.94

HD60

0.99

0.89

1.11

AHP/SHP48

1.00

1.00

1.00

AHX42

0.98

1.05

0.93

AHX48

0.98

1.07

0.92

AV/SV*48

0.98

1.05

0.94

F4FP045

1.01

1.07

0.94

F5FP048

0.99

1.01

0.98

F6FP042

0.99

1.06

0.94

F6FP048

0.99

1.09

0.91

MA14D

FC/MC/PC48D

1.00

1.00

1.00

MA16C

FC/MC/PC48C

1.00

1.00

1.00

MV16C

FC/MC/PC48C

0.99

0.99

1.00

MV20D

FC/MC/PC48D

0.98

0.98

1.00

MA14D

FC/MC/PC60D

1.00

1.06

0.94

MA16C

FC/MC/PC60C

1.00

1.06

0.94

MV20D

FC/MC/PC60D

0.98

1.04

0.94

Continued on next page.

32

Johnson Controls Unitary Products

Page 32
Image 32