HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)

MODEL

FURNACE

COIL1

 

 

 

ARI HEATING2

 

 

 

MODEL

MODEL

 

47°F

 

 

 

 

17°F

 

HSPF

 

 

 

MBH

COP

KW

 

MBH

 

COP

KW

STD

 

T*(8,L)X*C16

FC/PC60C

47.0

3.46

3.98

 

32.8

 

2.28

4.22

8.00

 

T*9X*C16

FC/PC60C

47.0

3.46

3.98

 

32.8

 

2.28

4.22

8.00

 

T*(8,L)X*C20

FC/MC/PC60D

47.0

3.48

3.96

 

32.8

 

2.28

4.22

8.00

 

T*9X*C20

FC/PC60C

47.0

3.48

3.96

 

32.6

 

2.30

4.15

8.00

 

T*9X*D20

FC/MC/PC60D

46.5

3.50

3.89

 

32.2

 

2.32

4.07

8.10

 

T*9X*D20

FC/MC62D

47.5

3.54

3.93

 

32.6

 

2.30

4.15

8.00

 

T*(8,L)X*C16

UC60C

47.5

3.58

3.89

 

32.6

 

2.34

4.08

8.10

 

T*(8,L)X*C20

UC60D

47.0

3.64

3.78

 

32.0

 

2.40

3.91

8.10

 

T*9X*C16

UC60C

47.5

3.58

3.89

 

32.6

 

2.34

4.08

8.00

 

T*9X*C20

UC60C

47.5

3.60

3.87

 

32.6

 

2.34

4.08

8.10

 

T*9X*D20

UC60D

46.5

3.60

3.79

 

32.0

 

2.38

3.94

8.10

 

(Y*9C/T*9V)*D20

FC/MC/PC60D

47.5

3.38

4.12

 

30.4

 

2.38

3.74

8.50

 

(Y*9C/T*9V)*D20

FC/MC62D

48.0

3.44

4.09

 

30.2

 

2.40

3.69

8.50

YHJD48S41S1

Y*(8,L)C*C16

FC/PC60C

47.5

3.40

4.09

 

30.4

 

2.40

3.71

8.50

Y*(8,L)C*C20

FC/PC60C

47.5

3.46

4.02

 

30.2

 

2.42

3.66

8.60

 

 

 

 

(Y*9C/T*9V)*C16

FC/PC60C

48.0

3.38

4.16

 

30.6

 

2.38

3.77

8.50

 

(Y*9C/T*9V)*C20

FC/PC60C

48.0

3.38

4.16

 

30.6

 

2.38

3.77

8.50

 

(Y*9C/T*9V)*D20

HC60

48.0

3.48

4.04

 

30.4

 

2.44

3.65

8.50

 

Y*(8,L)C*C16

HD60

47.0

3.22

4.28

 

30.2

 

2.24

3.95

8.40

 

Y*(8,L)C*C20

HD60

47.0

3.24

4.25

 

30.0

 

2.28

3.86

8.40

 

(Y*9C/T*9V)*C16

HD60

47.5

3.18

4.38

 

30.2

 

2.24

3.95

8.40

 

(Y*9C/T*9V)*C20

HD60

47.5

3.18

4.38

 

30.2

 

2.24

3.95

8.40

 

(Y*9C/T*9V)*D20

HD60

47.5

3.20

4.35

 

30.2

 

2.24

3.95

8.40

 

Y*(8,L)C*C16

UC60C

47.5

3.46

4.02

 

30.2

 

2.42

3.66

8.50

 

Y*(8,L)C*C20

UC60C

47.5

3.52

3.95

 

30.0

 

2.46

3.57

8.60

 

(Y*9C/T*9V)*C16

UC60C

48.0

3.44

4.09

 

30.4

 

2.42

3.68

8.50

 

(Y*9C/T*9V)*C20

UC60C

48.0

3.44

4.09

 

30.4

 

2.42

3.68

8.50

 

(Y*9C/T*9V)*D20

UC60D

48.0

3.44

4.09

 

30.2

 

2.42

3.66

8.50

 

T*(8,L)X*C20

FC/MC62D

56.5

3.60

4.60

 

32.6

 

2.46

3.88

8.10

 

T*9X*D20

FC/MC62D

56.5

3.44

4.81

 

34.0

 

2.34

4.26

8.00

YHJD60S41S1

(Y*9C/T*9V)*D20

FC/MC/PC60D

55.5

3.30

4.93

 

35.0

 

2.40

4.27

8.50

 

Y*(8,L)C*C20

FC/MC62D

55.5

3.42

4.76

 

34.6

 

2.44

4.16

8.60

 

(Y*9C/T*9V)*C20

FC/MC62D

56.0

3.36

4.88

 

35.0

 

2.40

4.27

8.60

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

3.Variable speed furnaces have B.O.D (Blower on Delay) standard.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.

Johnson Controls Unitary Products

17

Page 17
Image 17
York YHJD18 warranty Johnson Controls Unitary Products