COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

AIR HANDLER

 

COIL

 

 

 

COOLING

 

 

MODEL

MODEL

 

W

MODEL1

RATED

 

NET MBH

SEER

EER

 

CFM

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

13 SEER

HP WITH AHP / SHP / AHX / F*FP

 

 

 

 

YHJD18S41S1

AHP18

 

17

600

 

17.0

12.7

13.00

11.00

F4FP024

 

17

600

 

17.0

12.6

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AHP30

 

17

800

 

23.0

17.2

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

AHX30

 

17

820

 

24.0

18.5

14.50

12.50

YHJD24S41S1

 

 

 

 

 

 

 

 

 

 

AHX36

 

21

815

 

24.0

18.9

14.50

12.50

 

 

 

 

 

 

 

 

 

 

 

 

F6FP030

 

17

850

 

24.0

18.5

14.25

12.00

 

 

 

 

 

 

 

 

 

 

 

 

F6FP036

 

21

855

 

24.0

18.6

14.50

12.20

 

 

 

 

 

 

 

 

 

 

 

 

AHP36

 

21

1000

 

29.0

23.2

13.00

11.00

YHJD30S41S1

 

 

 

 

 

 

 

 

 

 

AHX36

 

21

1005

 

29.6

24.6

14.30

12.00

 

 

 

 

 

 

 

 

 

 

 

 

F6FP036

 

21

980

 

29.0

23.4

14.00

12.00

 

 

 

 

 

 

 

 

 

 

 

 

AHP36

 

21

1200

 

35.0

26.8

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

YHJD36S41S1

AHX36

 

21

1225

 

35.0

28.4

14.00

12.00

 

 

 

 

 

 

 

 

 

 

F4FP045

 

24

1200

 

35.0

26.8

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F6FP042

 

21

1405

 

35.0

31.2

14.00

12.00

 

 

 

 

 

 

 

 

 

 

 

 

AHP/SHP48

 

21

1400

 

41.5

31.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

AHX42

 

21

1395

 

41.5

32.0

14.25

12.00

 

 

 

 

 

 

 

 

 

 

 

 

AHX48

 

24

1445

 

41.5

32.8

14.25

12.00

YHJD42S41S1

 

 

 

 

 

 

 

 

 

 

F4FP045

 

24

1400

 

41.0

31.2

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

F5FP048

 

24

1450

 

41.0

32.6

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

F6FP042

 

21

1455

 

41.5

32.6

14.25

12.00

 

 

 

 

 

 

 

 

 

 

 

 

F6FP048

 

24

1380

 

41.5

32.4

14.00

11.50

 

 

 

 

 

 

 

 

 

 

 

 

AHP/SHP60

 

24

1600

 

47.0

36.0

14.00

11.50

 

 

 

 

 

 

 

 

 

 

 

 

AHX48

 

24

1660

 

48.0

36.4

14.50

12.00

YHJD48S41S1

 

 

 

 

 

 

 

 

 

 

F5FP048

 

24

1700

 

47.5

36.6

14.00

11.50

 

 

 

 

 

 

 

 

 

 

 

 

F5FP060

 

24

1700

 

47.5

36.8

14.00

11.50

 

 

 

 

 

 

 

 

 

 

 

 

F6FP048

 

24

1625

 

48.0

36.4

14.25

12.00

 

 

 

 

 

 

 

 

 

 

 

YHJD60S41S1

AHX60

 

24

1680

 

54.5

42.0

13.50

11.50

 

 

 

 

 

 

 

 

 

 

F6FP060

 

24

1710

 

56.5

42.0

13.50

11.50

 

 

 

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

— = Not applicable.

Johnson Controls Unitary Products

5

Page 5
Image 5
York YHJD18 warranty Seer HP with AHP / SHP / AHX / F*FP, YHJD60S41S1 AHX60