HEATING PERFORMANCE DATA

CONDENSING UNIT MODEL NO

YHJD24S41S1

 

 

 

 

 

 

 

EVAPORATOR COIL MODEL NO

AHP24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

ID CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING

ENTERING

 

600

 

 

800

 

 

1000

 

OUTDOOR UNIT

INDOOR COIL

 

 

 

 

 

 

 

 

 

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

 

 

 

 

 

 

 

 

 

 

 

 

60

28.4

2.1

4.0

30.1

2.0

4.3

31.8

2.0

4.6

60

 

 

 

 

 

 

 

 

 

 

70

26.7

2.2

3.6

28.4

2.2

3.9

30.1

2.1

4.1

 

 

 

 

 

 

 

 

 

 

 

 

80

25.1

2.3

3.2

26.8

2.3

3.5

28.5

2.2

3.7

 

 

 

 

 

 

 

 

 

 

 

 

60

23.4

1.9

3.5

24.5

1.9

3.7

25.7

1.9

3.9

47

 

 

 

 

 

 

 

 

 

 

70

22.0

2.0

3.2

22.2

2.0

3.3

22.4

2.0

3.3

 

 

 

 

 

 

 

 

 

 

 

 

80

20.6

2.1

2.9

19.9

2.0

2.9

19.1

2.0

2.8

 

 

 

 

 

 

 

 

 

 

 

 

60

20.7

1.9

3.2

21.9

1.9

3.4

23.1

1.9

3.5

40

 

 

 

 

 

 

 

 

 

 

70

19.3

1.9

2.9

20.4

2.0

3.1

21.6

2.0

3.2

 

 

 

 

 

 

 

 

 

 

 

 

80

17.9

2.0

2.7

19.0

2.0

2.8

20.0

2.1

2.9

 

 

 

 

 

 

 

 

 

 

 

 

60

17.2

1.7

2.9

18.1

1.8

3.0

19.0

1.8

3.0

30

 

 

 

 

 

 

 

 

 

 

70

15.8

1.8

2.6

16.7

1.8

2.7

17.6

1.9

2.7

 

 

 

 

 

 

 

 

 

 

 

 

80

14.3

1.8

2.3

15.2

1.9

2.4

16.2

1.9

2.5

 

 

 

 

 

 

 

 

 

 

 

 

60

7.9

1.6

1.5

11.2

1.6

2.0

14.4

1.7

2.5

17

 

 

 

 

 

 

 

 

 

 

70

9.0

1.6

1.7

11.0

1.7

1.9

13.0

1.7

2.2

 

 

 

 

 

 

 

 

 

 

 

 

80

10.0

1.6

1.8

10.9

1.7

1.9

11.7

1.7

2.0

 

 

 

 

 

 

 

 

 

 

 

 

60

10.5

1.5

2.1

11.2

1.6

2.1

11.9

1.6

2.1

10

 

 

 

 

 

 

 

 

 

 

70

9.3

1.5

1.8

9.9

1.6

1.9

10.6

1.6

1.9

 

 

 

 

 

 

 

 

 

 

 

 

80

8.0

1.5

1.6

8.6

1.6

1.6

9.3

1.6

1.7

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

Air Handlers

Coils

MBH

KW

COP

FC/MC/PC24

1.00

1.00

1.00

FC/MC/PC30

1.00

1.00

1.00

FC/MC/PC32

1.00

1.00

1.00

FC/MC/PC35

1.00

1.00

1.00

HC30

0.99

0.99

1.01

HC36

1.00

1.00

1.00

HD36

1.35

1.41

0.96

AHP30

1.01

1.01

1.00

AHX30

0.99

1.07

0.92

AHX36

0.99

1.12

0.89

AV24

0.96

0.95

1.01

AV*36

0.97

1.08

0.90

F4FP030

0.99

0.99

1.01

F6FP030

0.99

1.05

0.94

F6FP036

0.99

1.07

0.92

MA08B

FC/MC/PC24B

1.00

1.00

1.00

MV12B

FC/MC/PC24B

0.98

0.98

1.00

MA08B

FC/MC/PC30B

1.00

1.00

1.00

MV12B

FC/MC/PC30B

0.98

0.98

1.00

MA08B

FC/MC/PC35B

1.00

1.00

1.00

MV12B

FC/MC/PC35B

0.98

0.98

1.00

MV16C

FC/MC/PC35C

0.98

0.98

1.00

Furnaces

Coils

MBH

KW

COP

T*9X*B12

FC/MC/PC35B

0.98

1.08

0.91

T*(8,L)X*A12

FC/MC/PC37A

1.00

1.12

0.89

T*(8,L)X*B12

FC/MC/PC43B

1.00

1.13

0.89

T*9X*B12

FC/MC/PC43B

0.99

1.11

0.90

T*(8,L)X*B12

FC/MC/PC35B

0.99

1.10

0.90

T*9X*C16

FC/MC/PC35C

0.96

1.06

0.90

T*(8,L)X*A12

FC/MC/PC32A

0.98

1.08

0.90

Y*(8,L)C*A12

FC/MC/PC32A

0.98

1.04

0.95

Y*(8,L)C*B12

FC/MC/PC35B

0.98

1.05

0.93

(Y*9C/T*9V)*B12

FC/MC/PC35B

0.99

1.05

0.94

Y*(8,L)C*A12

FC/MC/PC37A

1.00

1.07

0.93

Y*(8,L)C*B12

FC/MC/PC43B

0.98

1.07

0.92

(Y*9C/T*9V)*B12

FC/MC/PC43B

0.99

1.07

0.93

Y*(8,L)C*B12

HC36

0.97

1.05

0.93

(Y*9C/T*9V)*B12

HC36

0.99

1.05

0.94

Y*(8,L)C*A12

HD36

0.90

0.90

1.00

Y*(8,L)C*B12

HD36

0.89

0.89

1.00

Y*(8,L)C*C16

HD36

0.91

0.93

0.98

Y*(8,L)C*C20

HD36

0.88

0.89

0.98

(Y*9C/T*9V)*B12

HD36

0.90

0.90

1.00

(Y*9C/T*9V)*C16

HD36

0.90

0.91

0.99

(Y*9C/T*9V)*C20

HD36

0.88

0.89

0.99

Johnson Controls Unitary Products