246750-YTG-L-0408

COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION

OUTDOOR UNIT MODEL NO.

YZE02411

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC36B + MV12B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

 

700

 

 

 

 

800

 

 

 

 

900

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

57

62

62

67

72

57

 

T.C.

23.9

24.9

23.7

27.3

29.1

25.2

25.8

24.6

28.0

30.0

26.5

26.7

25.4

28.8

30.9

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

22.6

21.7

18.0

18.9

14.6

23.8

23.1

19.5

20.3

15.7

24.9

24.5

21.0

21.6

16.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

23.4

24.1

23.0

26.1

28.0

24.6

24.9

23.7

26.9

28.8

25.9

25.8

24.4

27.6

29.6

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

22.1

21.5

17.7

18.3

14.3

23.2

22.9

19.1

19.7

15.4

24.3

24.3

20.5

21.0

16.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

22.9

23.2

22.2

25.0

26.9

24.1

24.1

22.8

25.7

27.6

25.2

24.9

23.5

26.4

28.3

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

21.6

21.2

17.4

17.8

14.0

22.7

22.6

18.8

19.2

15.0

23.6

24.1

20.1

20.5

16.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.7

1.8

1.7

1.8

1.8

1.7

1.8

1.7

1.8

1.8

1.8

1.8

1.7

1.8

1.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

22.4

22.4

21.5

23.9

25.8

23.5

23.2

22.0

24.6

26.4

24.6

24.0

22.5

25.3

27.1

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

21.2

20.9

17.1

17.3

13.6

22.1

22.4

18.4

18.6

14.7

23.0

23.8

19.7

19.9

15.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.9

1.9

1.9

2.0

2.0

1.9

2.0

1.9

2.0

2.0

2.0

2.0

1.9

2.0

2.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

21.3

21.1

20.0

22.5

24.1

22.4

22.0

20.5

23.2

24.7

23.4

22.8

21.0

23.8

25.3

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

20.2

20.0

16.4

16.8

13.2

21.0

21.2

17.6

18.1

14.1

21.8

22.3

18.9

19.4

15.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.2

2.2

2.2

2.3

2.3

2.2

2.2

2.2

2.3

2.3

2.2

2.3

2.2

2.3

2.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

20.3

19.9

18.7

21.2

22.5

21.3

20.8

19.2

21.7

23.0

22.2

21.6

19.6

22.3

23.5

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

19.2

19.1

15.6

16.3

12.7

19.9

20.0

16.9

17.6

13.6

20.6

20.9

18.1

18.9

14.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.5

2.5

2.5

2.5

2.6

2.5

2.5

2.5

2.5

2.6

2.5

2.5

2.5

2.5

2.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

19.3

18.8

17.3

19.8

20.9

20.2

19.6

17.8

20.3

21.3

21.0

20.4

18.2

20.8

21.7

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

18.2

18.2

14.9

15.8

12.3

18.8

18.9

16.1

17.1

13.1

19.4

19.4

17.3

18.4

14.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

HIGH CFM

 

 

 

 

 

 

 

 

 

Air Handler

Coil

T.C.

S.C.

KW

AV24

1.01

1.00

1.00

AV36

1.01

1.00

1.00

MV12B

FC/MC30B

0.96

1.05

0.99

MV12B

FC/MC35B

0.96

1.05

0.99

MV12B

FC/MC36B

1.00

1.00

1.00

MV12B

FC/MC42B

0.96

1.05

0.99

MV16C

FC/MC35C

1.00

1.00

1.00

MV16C

FC/MC42C

1.00

1.00

1.00

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

 

 

 

 

 

PV8*A12

FC/MC/PC30A

1.00

1.02

1.00

PV9*A12

FC/MC/PC30A

1.00

1.02

1.00

P(C,V)9*B12

FC/MC/PC30B

1.00

1.02

1.00

PV9*A12

FC/MC/PC32A

1.00

1.02

1.00

P(C,V)9*B12

FC/MC/PC35B

1.00

1.02

1.00

PV8*A12

FC/MC/PC36A

1.01

1.02

0.99

PV9*A12

FC/MC/PC36A

1.01

1.03

0.99

P(C,V)9*B12

FC/MC/PC36B

1.01

1.03

0.99

P(C,V)9*B12

FC/MC/PC42B

1.00

1.03

0.97

P(C,V)9*B12

HC30

1.00

1.03

0.97

P(C,V)9*B12

HC36

1.01

1.03

0.99

P(C,V)9*B12

HD36

1.01

1.03

0.99

PV8*A12

UC30A

1.00

1.03

0.97

P(C,V)9*B12

UC30B

1.00

1.03

0.97

PV8*A12

UC36A

1.01

1.03

0.99

P(C,V)9*B12

UC36B

1.01

1.03

0.99

P(C,V)9*B12

UC42B

1.01

1.03

0.99