![Manual background](/images/new-backgrounds/34931/3493141x1.webp)
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| |||||||
HEATING PERFORMANCE DATA - HIGH CFM |
|
|
|
|
| |||||||
OUTDOOR UNIT MODEL NO. | YZE02411 |
|
|
|
|
|
|
|
|
| ||
INDOOR COIL MODEL NO. | FC/MC/PC36B + MV12B |
|
|
|
|
|
|
| ||||
AIR TEMP. | AIR TEMP. |
|
|
|
|
| ID CFM |
|
|
|
|
|
ENTERING | ENTERING |
|
|
|
|
|
|
|
|
|
| |
|
| 700 |
|
| 800 |
|
| 900 |
| |||
OUTDOOR | INDOOR |
|
|
|
|
|
|
|
|
|
|
|
MBTUH |
| KW | C.O.P. | MBTUH | KW | C.O.P. | MBTUH |
| KW | C.O.P. | ||
UNIT | COIL |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 33.2 |
| 2.1 | 4.7 | 33.2 | 2.0 | 4.9 | 33.2 |
| 1.9 | 5.2 |
60 |
|
|
|
|
|
|
|
|
|
|
|
|
70 | 31.9 |
| 2.3 | 4.0 | 32.0 | 2.2 | 4.2 | 32.1 |
| 2.1 | 4.5 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 30.6 |
| 2.6 | 3.5 | 30.8 | 2.5 | 3.7 | 31.0 |
| 2.3 | 3.9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 25.1 |
| 2.0 | 3.7 | 25.8 | 1.9 | 3.9 | 26.4 |
| 1.8 | 4.2 |
47 |
|
|
|
|
|
|
|
|
|
|
|
|
70 | 24.2 |
| 2.3 | 3.1 | 25.0 | 2.2 | 3.4 | 25.8 |
| 2.1 | 3.6 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 23.3 |
| 2.5 | 2.7 | 24.2 | 2.4 | 2.9 | 25.2 |
| 2.4 | 3.1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 23.2 |
| 2.0 | 3.4 | 23.3 | 1.9 | 3.6 | 23.4 |
| 1.8 | 3.8 |
40 |
|
|
|
|
|
|
|
|
|
|
|
|
70 | 21.6 |
| 2.4 | 2.6 | 21.4 | 2.2 | 2.8 | 21.1 |
| 2.0 | 3.1 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 20.0 |
| 2.8 | 2.1 | 19.4 | 2.5 | 2.2 | 18.8 |
| 2.2 | 2.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 20.4 |
| 1.9 | 3.1 | 20.6 | 1.8 | 3.3 | 20.8 |
| 1.8 | 3.4 |
30 |
|
|
|
|
|
|
|
|
|
|
|
|
70 | 21.6 |
| 2.3 | 2.8 | 21.8 | 2.2 | 2.9 | 21.9 |
| 2.1 | 3.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 22.9 |
| 2.7 | 2.5 | 22.9 | 2.6 | 2.6 | 23.0 |
| 2.4 | 2.8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 16.9 |
| 1.8 | 2.7 | 16.6 | 1.8 | 2.7 | 16.3 |
| 1.7 | 2.8 |
17 |
|
|
|
|
|
|
|
|
|
|
|
|
70 | 15.6 |
| 2.0 | 2.3 | 15.6 | 1.9 | 2.4 | 15.6 |
| 1.9 | 2.4 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 14.3 |
| 2.1 | 2.0 | 14.6 | 2.1 | 2.1 | 15.0 |
| 2.1 | 2.1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 13.6 |
| 1.7 | 2.3 | 13.4 | 1.7 | 2.3 | 13.3 |
| 1.7 | 2.3 |
10 |
|
|
|
|
|
|
|
|
|
|
|
|
70 | 13.3 |
| 2.1 | 1.9 | 13.3 | 2.0 | 1.9 | 13.3 |
| 2.0 | 2.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 13.1 |
| 2.4 | 1.6 | 13.2 | 2.3 | 1.7 | 13.4 |
| 2.2 | 1.8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor section.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HIGH CFM
Air Handler | Coil | MBH | KW | COP |
AV24 | – | 1.00 | 1.00 | 1.00 |
AV36 | – | 1.00 | 1.00 | 1.00 |
MV12B | FC/MC30B | 0.99 | 1.00 | 0.99 |
MV12B | FC/MC35B | 0.99 | 1.00 | 0.99 |
MV12B | FC/MC36B | 0.99 | 1.00 | 0.99 |
MV12B | FC/MC42B | 0.99 | 1.00 | 0.99 |
MV16C | FC/MC35C | 0.99 | 1.00 | 0.99 |
MV16C | FC/MC42C | 0.99 | 1.00 | 0.99 |
Variable Speed | Coil | T.C. | S.C. | KW | |
Furnace | |||||
|
|
|
| ||
|
|
|
|
| |
PV8*A12 | FC/MC/PC30A | 0.99 | 1.00 | 0.99 | |
PV9*A12 | FC/MC/PC30A | 0.99 | 1.00 | 0.99 | |
P(C,V)9*B12 | FC/MC/PC30B | 0.99 | 1.00 | 0.99 | |
PV9*A12 | FC/MC/PC32A | 0.99 | 1.00 | 0.99 | |
P(C,V)9*B12 | FC/MC/PC35B | 0.99 | 1.00 | 0.99 | |
PV8*A12 | FC/MC/PC36A | 0.99 | 1.00 | 0.99 | |
PV9*A12 | FC/MC/PC36A | 0.99 | 1.00 | 0.99 | |
P(C,V)9*B12 | FC/MC/PC36B | 0.99 | 1.00 | 0.99 | |
P(C,V)9*B12 | FC/MC/PC42B | 0.99 | 1.00 | 0.99 | |
P(C,V)9*B12 | HC30 | 0.99 | 1.00 | 0.99 | |
P(C,V)9*B12 | HC36 | 0.99 | 1.00 | 0.99 | |
P(C,V)9*B12 | HD36 | 0.99 | 1.00 | 0.99 | |
PV8*A12 | UC30A | 0.99 | 1.00 | 0.99 | |
P(C,V)9*B12 | UC30B | 0.99 | 1.00 | 0.99 | |
PV8*A12 | UC36A | 0.99 | 1.00 | 0.99 | |
P(C,V)9*B12 | UC36B | 0.99 | 1.00 | 0.99 | |
P(C,V)9*B12 | UC42B | 0.99 | 1.00 | 0.99 |
Johnson Controls Unitary Products | 21 |