York YZE024 THRU 060 warranty Outdoor Unit Model No

Models: YZE024 THRU 060

1 28
Download 28 pages 34.72 Kb
Page 14
Image 14
Manual background

246750-YTG-L-0408

COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION

OUTDOOR UNIT MODEL NO.

YZE03611

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC48C + MV16C

 

 

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

 

750

 

 

 

 

800

 

 

 

 

850

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

57

62

62

67

72

57

 

T.C.

24.3

26.1

25.5

28.1

31.9

24.8

26.4

25.9

28.5

32.2

25.3

26.6

26.3

28.8

32.5

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

23.9

22.4

18.5

19.1

15.6

24.4

22.8

19.1

19.5

16.2

24.9

23.2

19.7

19.9

16.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.3

1.3

1.3

1.3

1.2

1.3

1.3

1.3

1.2

1.2

1.3

1.3

1.3

1.2

1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

23.2

24.9

24.5

27.0

30.6

23.7

25.2

24.8

27.3

30.9

24.2

25.4

25.2

27.6

31.1

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

22.8

21.6

18.1

18.5

15.3

23.3

22.1

18.7

19.0

15.8

23.8

22.6

19.2

19.5

16.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.4

1.5

1.5

1.5

1.5

1.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

22.1

23.6

23.4

25.9

29.4

22.6

23.9

23.7

26.2

29.5

23.1

24.2

24.1

26.4

29.7

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

21.7

20.8

17.7

17.9

15.0

22.2

21.4

18.2

18.5

15.4

22.7

22.0

18.8

19.1

15.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.8

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

21.0

22.3

22.4

24.8

28.1

21.5

22.7

22.6

25.0

28.2

21.9

23.0

22.9

25.2

28.3

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

20.7

20.0

17.3

17.3

14.6

21.1

20.7

17.8

18.0

15.0

21.6

21.4

18.3

18.7

15.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.0

2.0

2.0

2.0

1.9

2.0

2.0

2.0

1.9

1.9

2.0

2.0

2.0

1.9

1.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

19.8

20.9

20.9

23.1

26.1

20.3

21.2

21.1

23.3

26.2

20.7

21.6

21.4

23.5

26.4

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

19.5

19.1

16.3

16.6

13.9

20.0

19.8

16.9

17.3

14.2

20.4

20.4

17.4

18.0

14.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.3

2.3

2.3

2.3

2.2

2.3

2.3

2.3

2.3

2.2

2.3

2.3

2.3

2.3

2.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

18.7

19.5

19.4

21.5

24.2

19.1

19.8

19.6

21.7

24.3

19.5

20.2

19.9

21.9

24.5

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

18.4

18.3

15.4

16.0

13.3

18.8

18.9

16.0

16.6

13.5

19.2

19.4

16.5

17.3

13.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.7

2.6

2.6

2.6

2.6

2.7

2.6

2.6

2.6

2.6

2.6

2.6

2.6

2.6

2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

17.5

18.0

18.0

19.9

22.3

17.9

18.4

18.2

20.1

22.5

18.3

18.7

18.3

20.3

22.6

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

17.3

17.4

14.4

15.4

12.6

17.7

18.0

15.0

16.0

12.8

18.1

18.5

15.7

16.6

12.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

3.0

3.0

3.0

2.9

2.9

3.0

3.0

3.0

2.9

2.9

3.0

2.9

2.9

2.9

2.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

LOW CFM

Air Handler

Coil

 

T.C.

S.C.

KW

AV36

1.00

1.00

1.00

AV48

1.00

1.00

1.00

MV12B

FC/MC35B

0.98

0.98

1.00

MV12B

FC/MC42B

0.98

0.98

1.00

MV16C

FC/MC48C

1.00

1.00

1.00

MV12D

FC/MC48D

0.99

1.00

1.00

 

 

 

 

 

 

 

Variable Speed

 

Coil

 

T.C.

S.C.

KW

Furnace

 

 

 

 

 

 

 

 

P(C,V)9*B12

 

FC/MC/PC35B

 

0.92

0.89

0.98

PV8*B16

 

FC/MC/PC35B

 

0.92

0.89

0.98

P(C,V)9*C16

 

FC/MC/PC35C

 

0.92

0.89

0.98

PV8*C16

 

FC/MC/PC35C

 

0.92

0.89

0.98

PV8*C20

 

FC/MC/PC35C

 

0.92

0.89

0.98

P(C,V)9*C20

 

FC/MC/PC35C

 

0.92

0.89

0.98

PV8*B16

 

FC/MC/PC42B

 

0.92

0.89

0.98

P(C,V)9*B12

 

FC/MC/PC42B

 

0.98

1.05

1.02

P(C,V)9*C20

 

FC/MC/PC42C

 

0.92

0.89

0.98

P(C,V)9*C16

 

FC/MC/PC42C

 

0.92

0.89

0.98

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

PV8*C16

FC/MC/PC42C

0.98

1.05

1.02

PV8*C20

FC/MC/PC42C

0.98

1.05

1.02

P(C,V)9*C20

FC/MC/PC48C

0.97

0.93

0.98

P(C,V)9*C16

FC/MC/PC48C

0.97

0.93

0.98

PV8*C16

FC/MC/PC48C

1.00

1.08

1.00

PV8*C20

FC/MC/PC48C

1.01

1.09

1.00

P(C,V)9*D20

FC/MC/PC48D

1.00

1.07

1.00

PV8*C16

HC42

0.97

0.93

0.98

PV8*C20

HC42

0.97

0.93

0.98

PV8*B16

UC42B

0.97

0.93

0.98

P(C,V)9*B12

UC42B

0.97

0.93

0.98

PV8*C20

UC42C

0.97

0.93

0.98

PV8*C16

UC42C

0.97

0.93

0.98

P(C,V)9*C16

UC42C

0.97

0.93

0.98

P(C,V)9*C20

UC42C

0.97

0.93

0.98

P(C,V)9*C20

UC48C

0.97

0.93

0.98

PV8*C20

UC48C

0.97

0.93

0.98

PV8*C16

UC48C

0.97

0.93

0.98

P(C,V)9*C16

UC48C

0.97

0.93

0.98

P(C,V)9*D20

UC48D

0.97

0.93

0.98

14

Johnson Controls Unitary Products

Page 14
Image 14
York YZE024 THRU 060 warranty Outdoor Unit Model No