HEATING PERFORMANCE DATA - LOW CFM
OUTDOOR UNIT MODEL NO. | YZE06011 |
|
|
|
|
|
|
|
| ||
INDOOR COIL MODEL NO. | MC61D + MV20D |
|
|
|
|
|
|
| |||
AIR TEMP. | AIR TEMP. |
|
|
|
|
| ID CFM |
|
|
|
|
ENTERING | ENTERING |
|
|
|
|
|
|
|
|
|
|
|
| 1100 |
|
| 1150 |
|
| 1200 |
| ||
OUTDOOR | INDOOR |
|
|
|
|
|
|
|
|
|
|
MBTUH |
| KW | C.O.P. | MBTUH | KW | C.O.P. | MBTUH | KW | C.O.P. | ||
UNIT | COIL |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 44.8 |
| 3.1 | 4.2 | 45.8 | 3.1 | 4.3 | 46.7 | 3.1 | 4.4 |
60 |
|
|
|
|
|
|
|
|
|
|
|
70 | 44.4 |
| 3.6 | 3.7 | 44.9 | 3.5 | 3.7 | 45.5 | 3.5 | 3.8 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 44.0 |
| 4.0 | 3.2 | 44.1 | 4.0 | 3.3 | 44.3 | 3.9 | 3.3 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 38.6 |
| 3.1 | 3.7 | 38.6 | 3.0 | 3.8 | 38.7 | 2.9 | 3.9 |
47 |
|
|
|
|
|
|
|
|
|
|
|
70 | 37.4 |
| 3.4 | 3.2 | 37.6 | 3.4 | 3.3 | 37.8 | 3.3 | 3.3 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 36.2 |
| 3.8 | 2.8 | 36.6 | 3.8 | 2.8 | 36.9 | 3.7 | 2.9 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 34.0 |
| 3.0 | 3.3 | 34.4 | 2.9 | 3.4 | 34.8 | 2.9 | 3.6 |
40 |
|
|
|
|
|
|
|
|
|
|
|
70 | 33.3 |
| 3.4 | 2.9 | 33.5 | 3.3 | 3.0 | 33.8 | 3.2 | 3.1 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 32.7 |
| 3.7 | 2.6 | 32.7 | 3.6 | 2.6 | 32.8 | 3.6 | 2.7 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 24.7 |
| 2.9 | 2.5 | 23.3 | 2.8 | 2.4 | 21.9 | 2.8 | 2.3 |
30 |
|
|
|
|
|
|
|
|
|
|
|
70 | 25.8 |
| 3.3 | 2.3 | 24.9 | 3.3 | 2.2 | 23.9 | 3.2 | 2.2 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 26.8 |
| 3.7 | 2.1 | 26.4 | 3.7 | 2.1 | 26.0 | 3.6 | 2.1 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 22.6 |
| 2.8 | 2.4 | 22.4 | 2.8 | 2.4 | 22.1 | 2.7 | 2.4 |
17 |
|
|
|
|
|
|
|
|
|
|
|
70 | 20.5 |
| 3.1 | 2.0 | 20.3 | 3.0 | 2.0 | 20.0 | 3.0 | 1.9 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 18.4 |
| 3.4 | 1.6 | 18.2 | 3.3 | 1.6 | 17.9 | 3.3 | 1.6 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 16.8 |
| 2.6 | 1.9 | 16.6 | 2.6 | 1.9 | 16.5 | 2.6 | 1.9 |
10 |
|
|
|
|
|
|
|
|
|
|
|
70 | 17.1 |
| 3.0 | 1.7 | 16.9 | 3.0 | 1.7 | 16.7 | 2.9 | 1.7 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 17.4 |
| 3.4 | 1.5 | 17.1 | 3.4 | 1.5 | 16.9 | 3.3 | 1.5 |
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
LOW CFM
Air Handler | Coil | MBH | KW | COP |
F*FV060 | – | 1.00 | 1.00 | 1.00 |
AV60 | – | 1.00 | 1.00 | 1.00 |
MV20D | FC/MC60D | 1.00 | 1.00 | 1.00 |
MV20D | FC/MC62D | 1.00 | 1.00 | 1.00 |
Variable Speed | Coil | T.C. | S.C. | KW | |
Furnace | |||||
|
|
|
| ||
|
|
|
|
| |
P(C,V)9*D20 | FC/MC/PC60D | 0.98 | 0.98 | 1.00 | |
P(C,V)9*D20 | FC/MC62D | 0.98 | 0.98 | 1.00 | |
PV8*C20 | FC/PC60C | 0.98 | 0.98 | 1.00 | |
P(C,V)9*C20 | FC/PC60C | 0.98 | 0.98 | 1.00 | |
P(C,V)9*D20 | HC60 | 0.98 | 0.98 | 1.00 | |
PV8*C20 | HD60 | 0.98 | 0.98 | 1.00 | |
P(C,V)9*D20 | HD60 | 0.98 | 0.98 | 1.00 | |
P(C,V)9*D20 | FC/MC62D | 0.98 | 0.99 | 1.00 | |
P(C,V)9*C20 | UC60C | 0.98 | 0.99 | 1.00 | |
PV8*C20 | UC60C | 0.98 | 0.99 | 1.00 | |
P(C,V)9*D20 | UC60D | 0.98 | 0.99 | 1.00 |