York YZE024 THRU 060 warranty Physical and Electrical Data, YTG-L-0408, Model, request

Models: YZE024 THRU 060

1 28
Download 28 pages 34.72 Kb
Page 2
Image 2

246750-YTG-L-0408

Physical and Electrical Data

MODEL

 

YZE02411

YZE03611

 

YZE04811

YZE06011

 

 

 

 

 

 

Unit Supply Voltage

 

 

208-230V, 1φ, 60Hz

 

 

 

 

 

 

 

Normal Voltage Range 1

 

 

 

187 to 252

 

Minimum Circuit Ampacity

18.6

24.7

 

27.9

37.9

 

 

 

 

 

 

Max. Overcurrent Device Amps 2

30

40

 

45

60

Min. Overcurrent Device Amps 3

20

25

 

30

40

Multi-stage Compressor

 

Yes

Yes

 

Yes

Yes

 

 

 

 

 

 

 

Compressor Type

 

Scroll

Scroll

 

Scroll

Scroll

 

 

 

 

 

 

 

Compressor Amps

Rated Load

13.7

18.6

 

21.2

29.2

 

 

 

 

 

 

Locked Rotor

52

82

 

96

118

 

 

 

 

 

 

 

 

 

Crankcase Heater

 

No

No

 

No

No

 

 

 

 

 

 

 

Fan Motor Amps

Rated Load

1.5

1.5

 

1.5

1.5

 

 

 

 

 

 

 

Fan Diameter Inches

 

22

22

 

22

22

 

 

 

 

 

 

 

 

Rated HP

1/4

1/4

 

1/4

1/4

Fan Motor

 

 

 

 

 

 

Nominal RPM

850

850

 

850

850

 

 

 

 

 

 

 

 

Nominal CFM

3,250

3,300

 

3,050

3,100

 

 

 

 

 

 

 

 

Face Area Sq. Ft.

17.15

20.58

 

20.58

20.58

Coil

 

 

 

 

 

 

Rows Deep

1

1

 

2

2

 

 

 

 

 

 

 

 

Fins / Inch

22

22

 

22

22

 

 

 

 

 

 

 

Liquid Line Set OD (Field Installed)

3/8

3/8

 

3/8

3/8

 

 

 

 

 

 

Vapor Line Set OD (Field Installed)

3/4

3/4

 

7/8

7/8

 

 

 

 

 

 

Unit Charge (Lbs. - Oz.) 4

8 - 14

8 - 8

 

14 - 8

14 - 0

Charge Per Foot, Oz.

 

0.62

0.62

 

0.67

0.75

 

 

 

 

 

 

 

Operating Weight Lbs.

 

270

290

 

310

315

 

 

 

 

 

 

 

1.Rated in accordance with ARI Standard 110, utilization range “A”.

2.Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.

3.Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection .

4.The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

 

 

 

 

All dimensions are in inches. They are subject to change

 

 

 

 

without notice. Certified dimensions will be provided upon

 

 

 

 

request.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

Refrigerant

 

 

 

 

 

 

Unit

 

 

Connection

 

 

 

 

 

 

 

 

(Inches)

 

 

 

 

 

 

 

Model

 

 

 

Service Valve Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

B

 

C

Liquid

Vapor

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024

33-1/2

 

37

 

31

 

3/4”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

39-1/2

 

37

 

31

3/8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

39-1/2

 

37

 

31

7/8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

B

 

060

39-1/2

 

37

 

31

 

7/8”*

 

VAPOR

3-1/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

6-1/2

 

 

* Adapter fitting required for 1-1/8” line set.

 

 

 

 

 

 

 

 

2-3/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 