345094-YTG-D-0108

COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION

OUTDOOR UNIT MODEL NO.

YZH02411

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC/PC48D + MV12D

 

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

 

600

 

 

 

 

650

 

 

 

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

19.7

20.0

19.9

22.0

23.6

19.7

20.0

19.9

22.0

23.6

19.7

20.0

19.9

22.0

23.6

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

19.7

19.2

15.7

15.8

13.0

19.7

19.2

15.7

15.8

13.0

19.7

19.2

15.7

15.8

13.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

18.9

19.0

18.9

21.0

22.6

18.9

19.0

18.9

21.0

22.6

18.9

19.0

18.9

21.0

22.6

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

18.9

18.5

15.4

15.4

12.5

18.9

18.5

15.4

15.4

12.5

18.9

18.5

15.4

15.4

12.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

18.1

18.0

18.0

20.0

21.7

18.1

18.0

18.0

20.0

21.7

18.1

18.0

18.0

20.0

21.7

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

18.1

17.7

15.0

15.0

12.1

18.1

17.7

15.0

15.0

12.1

18.1

17.7

15.0

15.0

12.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.0

1.0

1.1

1.1

1.1

1.0

1.0

1.1

1.1

1.1

1.0

1.0

1.1

1.1

1.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

17.4

17.0

17.1

18.9

20.7

17.4

17.0

17.1

18.9

20.7

17.4

17.0

17.1

18.9

20.7

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

17.4

17.0

14.6

14.6

11.7

17.4

17.0

14.6

14.6

11.7

17.4

17.0

14.6

14.6

11.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

16.2

15.9

15.6

17.4

19.1

16.2

15.9

15.6

17.4

19.1

16.2

15.9

15.6

17.4

19.1

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

16.2

15.9

13.9

14.0

11.1

16.2

15.9

13.9

14.0

11.1

16.2

15.9

13.9

14.0

11.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

15.0

14.9

14.1

15.9

17.6

15.0

14.9

14.1

15.9

17.6

15.0

14.9

14.1

15.9

17.6

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

15.0

14.9

13.3

13.5

10.5

15.0

14.9

13.3

13.5

10.5

15.0

14.9

13.3

13.5

10.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.6

1.6

1.5

1.6

1.6

1.6

1.6

1.5

1.6

1.6

1.6

1.6

1.5

1.6

1.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

13.8

13.8

12.7

14.3

16.0

13.8

13.8

12.7

14.3

16.0

13.8

13.8

12.7

14.3

16.0

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

13.8

13.8

12.7

13.0

10.0

13.8

13.8

12.7

13.0

10.0

13.8

13.8

12.7

13.0

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

LOW CFM

 

 

 

 

 

 

 

 

 

Air Handler

Coil

T.C.

S.C.

KW

AV36

-

0.98

0.96

0.98

MV12B

FC/MC43B

0.98

0.96

0.97

MV12D

FC/MC60D

1.00

1.00

1.00

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

P(C,V)9*B12

FC/MC/PC43B

0.97

0.92

0.97

12

Unitary Products Group

Page 12