COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION
OUTDOOR UNIT MODEL NO. | YZH03611 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
INDOOR COIL MODEL NO. | FC/MC62D + MV12D |
|
|
|
|
|
|
|
|
|
|
| ||||
CONDENSER | ID CFM |
|
| 796 |
|
|
|
| 846 |
|
|
|
| 896 |
|
|
ENTERING AIR | ID DB (°F) | 80 | 80 | 75 | 80 | 80 | 80 | 80 | 75 | 80 | 80 | 80 | 80 | 75 | 80 | 80 |
TEMPERATURE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ID WB (°F) | 57 | 62 | 62 | 67 | 72 | 57 | 62 | 62 | 67 | 72 | 57 | 62 | 62 | 67 | 72 | |
| T.C. | 26.3 | 27.5 | 27.3 | 30.5 | 33.5 | 26.9 | 28.0 | 27.7 | 30.9 | 34.1 | 27.4 | 28.4 | 28.1 | 31.3 | 34.7 |
65 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S.C. | 26.3 | 23.9 | 20.3 | 20.4 | 16.7 | 26.9 | 25.0 | 20.9 | 21.0 | 17.1 | 27.4 | 26.1 | 21.6 | 21.6 | 17.5 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| K.W. | 1.0 | 1.0 | 1.0 | 1.0 | 1.1 | 1.0 | 1.0 | 1.0 | 1.0 | 1.1 | 1.0 | 1.0 | 1.0 | 1.0 | 1.1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| T.C. | 25.2 | 26.0 | 25.9 | 28.9 | 32.0 | 25.7 | 26.4 | 26.3 | 29.3 | 32.5 | 26.3 | 26.7 | 26.6 | 29.7 | 33.0 |
75 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S.C. | 25.2 | 23.6 | 19.8 | 19.8 | 16.1 | 25.7 | 24.4 | 20.4 | 20.5 | 16.5 | 26.3 | 25.2 | 21.0 | 21.1 | 16.9 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| K.W. | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| T.C. | 24.1 | 24.5 | 24.5 | 27.4 | 30.5 | 24.6 | 24.8 | 24.8 | 27.8 | 30.8 | 25.2 | 25.0 | 25.1 | 28.1 | 31.2 |
85 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S.C. | 24.1 | 23.2 | 19.3 | 19.3 | 15.5 | 24.6 | 23.8 | 19.9 | 19.9 | 15.9 | 25.2 | 24.3 | 20.5 | 20.5 | 16.3 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| K.W. | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| T.C. | 23.0 | 22.9 | 23.0 | 25.9 | 28.9 | 23.5 | 23.1 | 23.3 | 26.2 | 29.2 | 24.0 | 23.4 | 23.6 | 26.5 | 29.5 |
95 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S.C. | 23.0 | 22.9 | 18.7 | 18.8 | 15.0 | 23.5 | 23.1 | 19.3 | 19.4 | 15.3 | 24.0 | 23.4 | 19.9 | 20.0 | 15.6 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| K.W. | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| T.C. | 21.4 | 21.3 | 20.8 | 23.6 | 26.6 | 21.8 | 21.6 | 21.1 | 23.8 | 26.8 | 22.3 | 21.9 | 21.3 | 24.1 | 27.0 |
105 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S.C. | 21.4 | 21.3 | 17.9 | 18.0 | 14.2 | 21.8 | 21.6 | 18.4 | 18.6 | 14.5 | 22.3 | 21.9 | 18.9 | 19.2 | 14.9 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| K.W. | 1.8 | 1.8 | 1.8 | 1.8 | 1.9 | 1.8 | 1.8 | 1.8 | 1.8 | 1.9 | 1.8 | 1.8 | 1.8 | 1.8 | 1.9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| T.C. | 19.8 | 19.7 | 18.7 | 21.3 | 24.3 | 20.2 | 20.1 | 18.9 | 21.5 | 24.5 | 20.6 | 20.4 | 19.1 | 21.8 | 24.7 |
115 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S.C. | 19.8 | 19.7 | 17.1 | 17.3 | 13.4 | 20.2 | 20.1 | 17.5 | 17.9 | 13.8 | 20.6 | 20.4 | 17.9 | 18.5 | 14.1 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| K.W. | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| T.C. | 18.2 | 18.2 | 16.5 | 19.1 | 22.0 | 18.6 | 18.6 | 16.7 | 19.2 | 22.1 | 19.0 | 19.0 | 16.9 | 19.4 | 22.3 |
125 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S.C. | 18.2 | 18.2 | 16.4 | 16.5 | 12.6 | 18.6 | 18.6 | 16.6 | 17.1 | 13.0 | 19.0 | 19.0 | 16.9 | 17.7 | 13.4 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| K.W. | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
LOW CFM |
|
|
|
|
|
|
|
|
|
Air Handler | Coil | T.C. | S.C. | KW |
|
|
|
|
|
AV36 | - | 0.98 | 0.97 | 0.97 |
AV/SV48 | - | 1.01 | 1.04 | 0.98 |
MV16C | FC/MC43C | 0.97 | 0.93 | 0.95 |
MV16C | FC/MC48C | 0.98 | 0.95 | 0.96 |
MV12D | FC/MC48D | 0.97 | 0.91 | 0.96 |
MV12D | FC/MC60D | 0.97 | 0.93 | 0.97 |
Variable Speed | Coil | T.C. | S.C. | KW | |
Furnace | |||||
|
|
|
| ||
P(C,V)8*B16 | FC/MC/PC43B | 0.96 | 0.92 | 0.95 | |
P(C,V)8*C16 | FC/MC/PC43C | 0.93 | 0.84 | 0.94 | |
P(C,V)8*C20 | FC/MC/PC43C | 0.96 | 0.93 | 0.94 | |
P(C,V)9*B12 | FC/MC/PC43B | 0.96 | 0.93 | 0.94 | |
P(C,V)9*C16 | FC/MC/PC43C | 0.97 | 0.93 | 0.97 | |
P(C,V)9*C20 | FC/MC/PC43C | 0.97 | 0.94 | 0.95 | |
P(C,V)8*C16 | FC/MC/PC48C | 0.94 | 0.86 | 0.95 | |
P(C,V)8*C20 | FC/MC/PC48C | 0.97 | 0.94 | 0.95 | |
P(C,V)9*C16 | FC/MC/PC48C | 0.98 | 0.94 | 0.97 | |
P(C,V)9*C20 | FC/MC/PC48C | 0.98 | 0.95 | 0.95 | |
P(C,V)9*D20 | FC/MC/PC48D | 0.98 | 0.95 | 0.96 | |
P(C,V)8*C16 | FC/PC60C | 0.95 | 0.87 | 0.96 | |
P(C,V)8*C20 | FC/PC60C | 0.98 | 0.96 | 0.96 | |
P(C,V)9*C16 | FC/PC60C | 0.98 | 0.95 | 0.97 | |
P(C,V)9*C20 | FC/PC60C | 0.98 | 0.96 | 0.96 | |
P(C,V)9*D20 | FC/MC/PC60D | 0.97 | 0.95 | 0.96 | |
P(C,V)8*C20 | FC/MC62D | 0.97 | 0.94 | 0.96 | |
P(C,V)9*C20 | FC/MC62D | 0.98 | 0.95 | 0.96 | |
P(C,V)9*D20 | FC/MC62D | 0.98 | 0.95 | 0.96 | |
P(C,V)8*C16 | HC42 | 0.93 | 0.85 | 0.94 | |
P(C,V)8*C20 | HC42 | 0.96 | 0.93 | 0.95 | |
P(C,V)9*C16 | HC42 | 0.97 | 0.93 | 0.97 | |
P(C,V)9*C20 | HC42 | 0.98 | 0.94 | 0.95 |