345094-YTG-D-0108

 

 

 

 

 

 

HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION

 

 

 

 

 

OUTDOOR UNIT MODEL NO.

YZH06011

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC62D + MV20D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

 

ID CFM

 

 

 

 

 

ENTERING

ENTERING

 

 

 

 

 

 

 

 

 

 

 

 

 

1621

 

 

1721

 

 

1821

 

OUTDOOR

INDOOR

 

 

 

 

 

 

 

 

 

 

 

MBTUH

 

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

 

KW

C.O.P.

UNIT

COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

72.8

 

4.3

5.0

73.2

4.2

5.1

73.7

 

4.1

5.2

60

 

 

 

 

 

 

 

 

 

 

 

 

70

71.5

 

4.7

4.5

71.9

4.6

4.6

72.3

 

4.5

4.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

70.2

 

5.1

4.1

70.6

5.0

4.1

70.9

 

4.9

4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

60.3

 

4.0

4.4

60.5

3.9

4.5

60.8

 

3.9

4.6

47

 

 

 

 

 

 

 

 

 

 

 

 

70

59.4

 

4.4

4.0

59.7

4.3

4.1

59.9

 

4.2

4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

58.6

 

4.7

3.6

58.8

4.7

3.7

59.0

 

4.6

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

53.7

 

3.8

4.1

53.8

3.8

4.2

53.9

 

3.7

4.3

40

 

 

 

 

 

 

 

 

 

 

 

 

70

53.1

 

4.2

3.7

53.2

4.1

3.8

53.3

 

4.1

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

52.4

 

4.6

3.4

52.6

4.5

3.4

52.8

 

4.4

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

45.9

 

3.6

3.7

46.1

3.6

3.8

46.3

 

3.5

3.8

30

 

 

 

 

 

 

 

 

 

 

 

 

70

45.4

 

4.0

3.3

45.6

3.9

3.4

45.7

 

3.9

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

45.0

 

4.3

3.0

45.1

4.3

3.1

45.1

 

4.2

3.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

36.6

 

3.4

3.2

36.7

3.3

3.2

36.8

 

3.3

3.3

17

 

 

 

 

 

 

 

 

 

 

 

 

70

36.6

 

3.7

2.9

36.6

3.7

2.9

36.7

 

3.6

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

36.5

 

4.1

2.6

36.6

4.0

2.7

36.6

 

4.0

2.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

32.5

 

3.2

2.9

32.6

3.2

3.0

32.6

 

3.2

3.0

10

 

 

 

 

 

 

 

 

 

 

 

 

70

32.5

 

3.6

2.7

32.5

3.5

2.7

32.6

 

3.5

2.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

32.5

 

3.9

2.4

32.5

3.9

2.5

32.6

 

3.8

2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

HIGH CFM

 

 

 

 

 

 

 

 

 

Air Handler

Coil

MBH

KW

COP

AV/SV60

-

1.00

0.98

1.02

MV20D

 

1.00

1.00

1.00

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

 

 

 

 

 

P(C,V)8*C20

FC/PC60C

1.00

0.97

1.03

P(C,V)9*C20

FC/PC60C

1.00

0.97

1.03

P(C,V)9*D20

FC/MC/PC60D

1.00

0.97

1.03

P(C,V)8*C20

FC/MC62D

1.00

0.97

1.03

P(C,V)9*C20

FC/MC62D

1.00

0.97

1.03

P(C,V)9*D20

FC/MC62D

1.00

0.97

1.03

Unitary Products Group

27

Page 27
Image 27
York YZH024 THRU 060 warranty 1621 1721 1821