345094-YTG-D-0108

HEATING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION

 

 

 

 

OUTDOOR UNIT MODEL NO.

YZH04811

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC62D + MV20D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

 

ID CFM

 

 

 

 

ENTERING

ENTERING

 

 

 

 

 

 

 

 

 

 

 

 

973

 

 

1023

 

 

1073

 

OUTDOOR

INDOOR

 

 

 

 

 

 

 

 

 

 

MBTUH

 

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

UNIT

COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

41.4

 

2.5

4.9

41.6

2.5

5.0

41.8

2.4

5.1

60

 

 

 

 

 

 

 

 

 

 

 

70

40.7

 

2.8

4.3

40.8

2.7

4.3

40.9

2.7

4.4

 

 

 

 

 

 

 

 

 

 

 

 

 

80

40.0

 

3.1

3.8

40.0

3.0

3.8

40.0

3.0

3.9

 

 

 

 

 

 

 

 

 

 

 

 

 

60

33.7

 

2.4

4.0

33.8

2.4

4.1

34.0

2.4

4.2

47

 

 

 

 

 

 

 

 

 

 

 

70

33.2

 

2.7

3.6

33.3

2.7

3.7

33.4

2.6

3.7

 

 

 

 

 

 

 

 

 

 

 

 

 

80

32.8

 

3.0

3.2

32.8

2.9

3.3

32.8

2.9

3.3

 

 

 

 

 

 

 

 

 

 

 

 

 

60

29.7

 

2.4

3.7

29.8

2.3

3.7

29.9

2.3

3.8

40

 

 

 

 

 

 

 

 

 

 

 

70

29.4

 

2.6

3.3

29.4

2.6

3.3

29.4

2.6

3.4

 

 

 

 

 

 

 

 

 

 

 

 

 

80

29.1

 

2.9

2.9

29.0

2.9

3.0

28.9

2.8

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

60

24.4

 

2.3

3.1

24.4

2.3

3.2

24.5

2.2

3.2

30

 

 

 

 

 

 

 

 

 

 

 

70

24.2

 

2.6

2.8

24.1

2.5

2.8

24.1

2.5

2.8

 

 

 

 

 

 

 

 

 

 

 

 

 

80

23.9

 

2.8

2.5

23.8

2.8

2.5

23.7

2.7

2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

60

18.1

 

2.2

2.4

18.2

2.2

2.5

18.2

2.1

2.5

17

 

 

 

 

 

 

 

 

 

 

 

70

18.0

 

2.5

2.1

18.0

2.4

2.2

18.1

2.4

2.2

 

 

 

 

 

 

 

 

 

 

 

 

 

80

17.8

 

2.7

1.9

17.9

2.7

2.0

18.0

2.6

2.0

 

 

 

 

 

 

 

 

 

 

 

 

 

60

15.0

 

2.2

2.0

15.0

2.1

2.1

15.0

2.1

2.1

10

 

 

 

 

 

 

 

 

 

 

 

70

14.8

 

2.4

1.8

14.9

2.4

1.8

14.9

2.4

1.9

 

 

 

 

 

 

 

 

 

 

 

 

 

80

14.6

 

2.7

1.6

14.7

2.6

1.6

14.9

2.6

1.7

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multipliers for determining the performance with other indoor sections.

 

 

 

 

 

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

 

 

 

 

 

 

 

 

LOW CFM

 

 

 

 

 

 

 

 

 

Air Handler

Coil

MBH

KW

COP

AV/SV48

-

1.00

0.98

1.02

AV/SV60

-

1.00

0.98

1.02

MV16C

FC/MC48C

1.00

0.98

1.02

MV20D

FC/MC48D

1.00

0.98

1.02

MV20D

FC/MC60D

1.00

0.98

1.02

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

P(C,V)8*C16

FC/MC/PC48C

0.98

0.98

1.02

P(C,V)8*C20

FC/MC/PC48C

1.00

0.98

1.02

P(C,V)9*C16

FC/MC/PC48C

1.00

1.00

1.00

P(C,V)9*C20

FC/MC/PC48C

1.00

0.97

1.03

P(C,V)9*D20

FC/MC/PC48D

1.00

0.97

1.03

P(C,V)8*C16

FC/PC60C

0.98

0.98

1.02

P(C,V)8*C20

FC/PC60C

1.00

0.98

1.02

P(C,V)9*C16

FC/PC60C

0.98

1.03

0.97

P(C,V)9*C20

FC/PC60C

0.98

1.03

0.97

P(C,V)9*D20

FC/MC/PC60D

1.00

0.97

1.03

P(C,V)8*C20

FC/MC62D

1.00

0.98

1.02

P(C,V)9*C20

FC/MC62D

0.98

1.03

0.97

P(C,V)9*D20

FC/MC62D

1.00

0.97

1.03

24

Unitary Products Group

Page 24
Image 24
York YZH024 THRU 060 warranty 973 1023 1073