The Cell Number is got from the site survey operation by the doing ¡°i wli st ¡±command.

We recommend that user uses the following scenario under the Managed (Infrastructure) or Adhoc mode. One can first do the site survey command by the following command:

iwlist ethX scanning

Then, associate with the AP with the Cell number got from the iwlist command.

iwpriv ethX connect <Cell Number>

3.4.7 Dynamical Region Setting(For 802.11b/g only)

From ver 1.5, you can dynamically change the region settings. With different regions, the allowed channels are different. The private commands to get/set region information includes :

1.get_Region : To get the current region setting iwpriv ethX connect <Cell Number>

2.set_Region : To set the region

iwpriv ethX connect <Cell Number>

RegionI

Region String

Chann

Countries

D

 

el

 

1

USA

1-11

USA,Canada,Argentina,Brazil,Ukraine,China,Hong

 

 

 

Kong

 

 

 

,Korea,NewZealand

2

Taiwan/Euro

1-13

Taiwan, Europe, Spain, Austria, Belgium,

 

pe

 

Switzerland, Australia

3

France

10-13

France, Singapore

4

Japan

1-14

Japan

5

Israel

3-9

Israel

6

Mexico

10-11

Mexico

 

The table of region id and region string

3.4.8 Activate MIC Fail Counter Measure Feature

The feature will disable the network connection for one minutes when you get two MIC fail frame in one minute. The feature is initially disabled. You can activate the feature by using the apdbg tool.

apdbg ethX s_mic_cnt 0 1

8

Page 8
Image 8
Z-Com XG-762N manual Dynamical Region SettingFor 802.11b/g only, Activate MIC Fail Counter Measure Feature