39
Important: The wires in the mains lead fitted
to the appliance are coloured in accordance
with the following code.
Green and yellow -Earth
Blue -Neutral
Brown -Live
As the colours of the wires in the mains lead
of this appl iance may not correspond with
the coloured markings identifying the
terminals in your plug, proceed as follows:-
The wire which is coloured green and yellow
must be connected to the terminals in the
plug which is marked with the letter E or by
the earth symbol ( ) or colour ed green or
green and yellow. The wire which is
coloured blue, must be connected to the
terminal which is marke d with the letter N or
coloured black. The wire which is coloured
brown, must be connected to the terminal,
which is marked with the letter L or coloured
red.
Ensure that the cable does not become
trapped when pushing the appliance into
position.
If a moulded plug is fitted.
In the event of replacing a fuse in the plug
supplied a 3 amp ASTA approved fuse to
B.S. 1362 must be fitted.
Note: The fuse cover must be refitted when
changing the fuse. In the event of losing the
fuse cover the plug must not be used until a
replacement fuse cover has been obtained
and fitted.
Connecting to gas supply
This appliance is designed to be installed
with an appliance flexible connection only.
Supply piping should not be less than R
3
/8.
Connection is made to the Rc ½ (½” B.S.P.)
female threaded entry pipe located just
below the hotplate level on the rea r left hand
side of the appliance. NOTE: ONLY LIQUID
SEALANTS TO BE USED WHEN INL ET
GAS PIPE IS FITTED I.E.: DO NOT USE
P.T.F.E. SEALANT TAPE.