40
Carry out a gas tightness test after
connecting to the gas supply. The gas
bayonet connector must be fitted in the
shaded area indicated in Fig.2. Take into
account that it must be possible to pull the
appliance forward sufficiently. Ensure the
hose does not become trapped when
pushing the appliance into position.
IMPORTANT: FLEXIBLE TUBING U SED
MUST COM PLY WITH BS.669 CURRENT
EDITION.
LPG Flexible connections must be a type
suitable for L.P.G and capable of operation
up to 50 mbar and carry a red stripe, band or
label.
Fitting the stability bracket
It is recommended that if the ap pliance is to
be installed with a flexible supply pipe, a
stability bracket be fitted and is available
from your supplier (see Important Safety
Requirements). These instructions should
be read in conjunction with any leaflet
packed with the stability bracket.
1. Place the appliance in its intended
position and level appliance.
2. Mark off 300mm from the left hand side
of the a ppliance as sho wn in di mension
'A', Fig 3a. This is the centre line of the
fixing bracket.
3. Draw a l ine 100mm from the front edge
of the feet (see Fig.3a) and remove
appliance from its position. Mark off
dimension 'B' (see Fig.3a) back from this
line on the centre line of the br acket to
locate the front edge of the lower
bracket. Fix lower bracket (with two
fixing holes) to the floor then measure
the height from floor level to engagement
edge on back of appliance, dimension 'C'
of Fig. 3b.
487mm (B)
300mm
100mm
20mm
(A)
(C)
Fig.3a.
Fig
.3b.
250
850
450
700
400
50
100
Fig.2.