38
Levelling the appliance
Adjustment to suit floor conditions or height
is obtained by rotating clockwise or anti
clockwise the feet at the front and rear of the
appliance. A spirit level should be placed on
one of the shelves to confirm the appliance
is correctly levelled.
Connecting to electricity supply
Warning: This appliance must be
earthed.
Do not earth this applianc e to the
gas supply piping.
Connect to 230-240 A.C supply
only.
Connection to the electricity supply should
be made via a properly earthed, readily
accessible wall socket. Which is adjacent to,
but not directly above and not more than
1.7m away from the appliance and capable
of electrical isolation. The cooker point
should be within 1.7m of the appliance to
make it accessible to switch off the
appliance in case of emergency. The mains
lead should be routed so that it cannot touch
hot parts of the cooker i.e. the back panel
above a height of 650mm from the floor.
Should this plug not fit the socket outlet in
your home it should be cut off and replaced
with a suitable plug as outlined below.
If the moulded plug is cut from the cable
for any reason it must be destroyed or
disposed of safely, as protruding wires
will be an electrical shock hazard.
If the fitted plug is removed.
The flexible mains lead must be correctly
connected as below to three pin plug of not
less than 13amp capacity. If a B.S. 1363
fused plug is used, it must be fitted with a 3
amp fuse which is approved to B.S. 1362.