3)Connect the brown (live) wire to the terminal in the plug which is marked with the letter 'L' or coloured red.
Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.
A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely.
The replacement of electric cable must be carried out ex- clusively by the service force centre or by personnel with similar competencies, in accordance with the current regu- lations.
Permanent Connection
In the case of a permanent connection, it is necessary that you install a double pole switch between the hob and the electricity supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations.
The switch must not break the yellow and green earth cable at any point.
Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 50 deg. C.
Wiring diagram
23