INSTALLATION INSTRUCTIONS

It is dangerous to alter the specifications or attempt to modify this product in any way.

Technical information

DIMENSIONS

HEIGHT OF CANOPY:

 

100mm

 

HEIGHT OF CHIMNEY:

(UPPER SECTION)

415mm

 

 

(LOWER SECTION)

740mm

 

WIDTH OF CANOPY:

 

898mm

 

DEPTH OF CANOPY:

 

507mm

ELECTRICAL SUPPLY

VOLTAGE:

(~50Hz)

230V

 

POWER CONSUMPTION:

 

230W

 

FAN MOTOR:

 

150W

 

LAMPS:

(4x20W)

80W

SUITABLE FOR -

 

 

 

INSTALLATION ABOVE: ELECTRIC HOB:

(Maximum)

7KW

 

GAS HOB:

(Maximum)

10KW

 

SLOT-IN ELECTRIC COOKER: (Maximum)

12.4KW

 

SLOT-IN GAS COOKER:

(Maximum)

13.5KW

Note: CE Marking certifies that this appliance complies with the requirements laid down in EEC directive 89:336 (Electromagnetic compatibility) and subsequent modifications and Low Voltage directive 72/23/E.

DOUBLE INSULATED DO NOT EARTH

Electrical Requirements

Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety this should be undertaken by a qualified electrician e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC).

Electrical Connection

Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker

This appliance is fitted with a 2 core mains cable and must be permanently connected to the electricity supply via a double-pole switch having 3mm minimum contact gap on each pole. A Switched Fuse Connection Unit to BS.1363 Part 4, fitted with a 3 Amp fuse, is a recommended mains supply connection accessory to ensure compliance with the Safety Requirements applicable to fixed wiring instructions.

This appliance conforms to BS.800:1988 and EEC Directive No. 78 308 regarding suppression of radio and television interference.

Page 10

Page 10
Image 10