Connecting the terminal board
cablemustbeconnectedtoterminal .Afterconnectingthe
supply cable to the terminal board, secure it with a junction clamp.
Electrical connection with the hob
This oven can be connected to hobs indicated in the paragraph "Technical data". The socket for connecting the hob is located at the top of the oven cabinet. The hobs come complete with connecting leads for the hot plates/ heat areas and ground cable; these leads feature
The
The Manufacturer disclaims any liability in case these
Building-in
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fig. 8 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
1 | 2 | 3 | 4 | 5 |
|
|
|
|
|
|
|
|
| ||||||
| 230V 3~ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ø 4x2,5mm² L1 |
|
| L2 |
|
| L3 PE | |||||||||||||
| 1 | 2 | 3 | 4 | 5 |
|
|
|
|
|
|
|
|
| |||||
| 230V 1~ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ø 3x2,5mm² L1 |
|
|
|
| N |
|
| PE | |||||||||||
| 1 | 2 | 3 | 4 | 5 |
|
|
|
|
|
|
|
|
| |||||
| 400V 2N~ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Ø 4x2,5mm² L1 L2 |
|
| N |
|
|
| PE | ||||||||||||
| 1 | 2 | 3 | 4 | 5 |
|
|
|
|
|
|
|
|
| |||||
| 400V 3N~ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| PE | |||||||
Ø 5x1,5mm² L1 L2 L3 N |
|
|
|
Fig. 9
To ensure correct operation of the
Overall oven dimensions (Fig. 10)
Fig. 10
38