Technical data
Heating element ratings
Bottom heating element | 1000 W |
Top Heating element | 800 W |
Full oven (Top+Bottom) | 1800 W |
Fan cooking | 2000 W |
Grill | 1650 W |
Oven light | 25 W |
Hot air fan motor | 25 W |
Cooling fan motor | 25 W |
Total rating | 2075 W |
Operating voltage (50 Hz) | 230 V |
Dimensions of the recess
Height | mm 600 |
Width | mm 560 |
Depth | mm 550 |
Oven |
|
Height | mm 335 |
Width | mm 395 |
Depth | mm 400 |
Oven capacity | 53 l |
Instructions for the Installer
This appliance can be connected to the below listed ceramic hobs:
Type: ZVD 868 |
|
(with 2 |
|
Maximum power absorbed: | 7,6 kW |
Power supply voltage | (50 Hz) 230 V |
Type: ZK 630 L - ZK 630 F |
|
(with 2 |
|
Maximum power absorbed | 7,6 kW |
Power supply voltage | (50 Hz) 230 V |
Type: ZC 6695 |
|
(with 1 |
|
Maximum power absorbed | 6,4 kW |
Power supply voltage | (50 Hz) 230 V |
Type: ZC 6675
(without
Maximum power absorbed | 5,8 kW |
Power supply voltage | (50 Hz) 230 V |
Maximum Total Power Rate |
|
Oven + ceramic hob | 9,675 kW |
The instructions given below are designed specifically for a qualified installer and should aid him or her to perform all installation, adjustment, and maintenance operations with absolute precision and in compliance with all current legislation and regulations. We strongly recommend that all operations for the installation of your cooker be carryed out by Qualified Personnel in accordance with existing rules and regulations.
Electrical connection
Priortomakingtheelectricalconnection,makesurethat:
—the protection fuse and the domestic wiring system are suitable to carry the total electric load of the oven (see rating plate);
—your domestic wiring system has an efficient earth connection in compliance with rules and laws in force;
—the wall socket or the omnipole switch used for the electrical connection can easily be reached after the oven is built in.
This appliance is delivered without an electric supply cable, therefore, you will have to fit to it a supply cable with standard plug,suitableforthetotalelectricloadshownontheratingplate. The plug is to be inserted into a suitable wall socket. If you requireadirectconnectiontotheelectricnetwork(mains),itwill be necessary to fit between the appliance and the mains an omnipole switch, with a minimum gap between contacts of 3 mm,suitablefortherequiredloadandincompliancewithrules inforce.Thegreen&yellowgroundwiremustnotbeinterrupted
37