Propane to Natural Gas Installation Instructions

SECTION 3 - SERVICING COMPONENTS

Appendix - Instructions for Service Kit 36863 - Gas Conversion Kit for PS360EWB/WB70 with Midco Burner, Propane to Natural Gas, 1/98

Middleby Cooking Systems Group • 1400 Toastmaster Drive • Elgin, IL 60120 • (847)741-3300 • FAX (847)741-4406

Middleby Marshall®

Oven Gas Conversion Kit p/n 36863

PS360EWB and PS360WB70

Propane to Natural Gas Installation Instructions

WARNING

This conversion kit is to be installed by a Middleby Marshall Authorized Service Organization in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage. The authorized service organization performing this work assumes responsibility for this conversion.

This kit consists of the following parts:

Qty.

Units

p/n

Description

1

ea.

36862

Instructions for Conversion of Propane Operation to Natural Gas Operation, PS360EWB and

 

 

 

PS360WB70

1

ea.

31818

Orifice, Pilot Assembly - Natural Gas, 0.032” (0.81mm)

1

ea.

31821

Orifice, Main - Natural Gas, 0.234” (5.94mm)

1

ea.

22174-0006

Orifice, Low Flame - Nat. Gas, 0.065” (1.65mm, #53 drill) - used for converting PS360WB70 only

1

ea.

22500-0064

Label, NAT, Green

1

ea.

22500-0123

Label, Conversion - Gas

IMPORTANT

When converting any oven that is installed at an altitude above 5000 ft. (1524m), consult Middleby before installing this Kit.

1. PREPARATION

1.1Turn off the electric power supply to the oven.

1.2Turn off the gas supply at the service valve behind the oven.

WARNING

Before performing any service or conversion work, the electrical power supply AND the gas supply MUST be turned off.

1.3Open the machinery compartment access door.

2. PILOT ORIFICE REPLACEMENT

2.1Unscrew the brass fittings at both ends of the aluminum pilot tubing that connects the pilot orifice to the combination gas control valve. This allows the tubing to be removed. See Figure 1.

Figure 1

Conversion component locations

 

Solenoid valve

 

 

(PS360WB70 only)

Main

 

 

 

 

orifice

Low flame bypass

 

holder

 

 

(PS360WB70 only)

 

 

Combination gas

 

 

control valve

 

Pilot

 

 

 

 

orifice

 

 

Aluminum

 

 

pilot tubing

 

 

 

p/n 36862

P. Jan. 98 Rev B

Page 1 of 4