Yellow “NAT.” label placement

SECTION 3 - SERVICING COMPONENTS

Appendix - Instructions for Service Kit 36863 - Gas Conversion Kit for PS360EWB/WB70 with Midco Burner, Propane to Natural Gas, 1/98

9. CONVERSION LABELING

9.1Remove and discard the round, red “LPG.” label from the front face of the burner plenum.

9.2Apply the round, green “NAT.” label (p/n 22500-0064) to the front face of the burner housing as shown in Figure 7.

9.3Close the machinery compartment access door.

9.4Record the information requested on the silver conversion information label. Figure 8 shows a representation of this label.

9.5Apply the conversion information label to the front of the machinery compartment access door, next to the control panel. See Figure 9.

Figure 7

Yellow “NAT.” label placement

(on burner housing)

Upper oven

Lower oven

label location

label location

Figure 8

Conversion information label

Signature of technician

Date of conversion

performing conversion

 

NATURAL

THIS APPLIANCE HAS BEEN CONVERTED ON _______________ TO ______________ GAS WITH KIT

36863

 

 

 

 

 

 

 

 

NO. ________________ BY _______________ , WHO ACCEPTS THE RESPONSIBILITY FOR

THE CORRECTNESS OF THIS CONVERSION.

 

 

 

 

 

 

MAIN BURNER ORIFICE SIZE

 

 

 

 

 

MODEL NO.

 

 

.234”/5.94mm

MANIFOLD PRESSURE

 

 

INPUT RATING

 

MAXIMUM INLET PRESSURES

 

 

 

 

175,000 BTU

14” W.C./34.9mbar

 

 

 

 

 

 

 

 

 

 

Stated on the

 

 

 

 

Measured value

oven’s data plate

 

 

 

 

recorded in Step 8.3

Figure 9