Electrical connection
This appliance must be earthed.
The manufacturer declines any responsibility should this safety measures not be observed.
If the plug that is fitted to your appliance is not suitable for the socket, it must be cut off and the appropriate plug fitted.
Important
The wires on the mains lead are coloured in accordance with the following code:
Green and Yellow |
|
Blue |
|
Brown |
|
If you fit your own plug, the colours of the wires in the mains lead of your appliance may not correspond with the markings identifying the terminals in your plug.
Proceed as follows:
1.Connect the Green and Yellow (earth) wire to the terminal in the plug which is marked with the letter "E" or the earth symbol or coloured green and yellow.
2.Connect the Blue (neutral) wire to the terminal in the plug which is marked with the letter "N" or coloured black.
3.Connect the Brown (live) wire to the terminal in the plug which is marked with the letter "L" or coloured red.
The plug moulded onto the lead incorporates a 13amp BSI362 fuse. Only ASTA or BSI fuses should be used.
The plug must not be used if the fuse cover/carrier is lost. The cover/carrier is indicated by the coloured insert at the base of the product.
A replacement cover/carrier must be obtained from your local Service Force Centre.
This appliance complies with the following E.E.C. Directives:
-73/23 or 19.2.73 (Low Voltage Directive) and subsequent modifications;
-89/336 or 3.5.89 (Electromagnetic Compatibility Directive) and subsequent modifications.
CE03
28 | PWA02UK |