Charging Battery Packs with the LI72
Plug the LI72 into the appropriate A.C. wall receptacle, and then insert the charge cable into the battery pack charger jack.
The yellow/green charge indicator LED will indicate the status of the charger as per the following table.
Do not charge batteries with the
Indicator | Charger | Charger Status | |
Function | |||
|
| ||
|
|
|
Steady yellow indicator
Slow (1 Hz) flashing yellow indicator
Fast (4 Hz) flashing green indicator
Slow (1 Hz) flashing green indicator
Fast (4 Hz) flashing yellow indicator
Steady green indicator
Slow (1 Hz) flashing alternate yellow and green indicator
Standby | AC power on; no battery | |
| being charged | |
| Charger is applying | |
| trickle charge current | |
| (5% of maximum) to | |
bring a cold battery | ||
| temperature up to 0°C | |
| before starting a full | |
| charge cycle | |
| Charger is applying the | |
Rapid Charge | maximum charge rate to | |
| the battery | |
| Charger is in trickle | |
Maintain | charge mode(10% of | |
| nominal charge value). | |
| The battery may have | |
| an internal short, or | |
| its charge monitoring | |
Error | circuitry may be | |
| malfunctioning. The | |
| battery pack should not | |
| be used any further. | |
Ready | No charge is being | |
applied to the battery | ||
| ||
| Battery temperature is | |
| too hot. Charging will | |
Wait | not begin until battery | |
| temperature reaches | |
| 45°C. | |
|
|
Charging will cease three (3) hours after the charger has entered the “Maintain” mode.
14
QL Plus Series User Guide