rectly under the battery being charged will turn on if the battery is properly inserted.
The indicators under the battery will allow you to monitor the charging process per the table below:
| Amber | Green | Battery Status |
|
| On | Off | Charging |
|
| On | Flashing | 80% charged (O.K. |
|
| to use) |
| ||
|
|
|
| |
| Off | On | Completely |
|
| Charged |
| ||
|
|
|
| |
| Flashing | Off | Fault |
|
|
|
|
|
|
|
|
|
|
|
Important • A fault condition is caused by a problem with the battery. The charger may indicate a fault because the battery is too hot or cold to charge reliably. Try to charge the battery again when it returns to the room’s ambient temperature. If the amber indicator starts flashing on the second attempt, the battery should be discarded. Always dispose of batteries in a proper manner as described in Appendix E.
Quad Charger Cycle Times :
| Battery | QL 220Plus & | QL 420 |
|
| Status | QL 320 Plus | Plus |
|
| Battery 80% | 1.25 Hrs. | 2.5 Hrs. |
|
| Charged |
| ||
|
|
|
| |
|
|
|
|
|
| Battery Fully | 2.5 Hrs. | 5 Hrs. |
|
| Charged |
| ||
|
|
|
| |
|
|
|
|
|
Note • These times are for completely discharged batteries.
Battery packs which are only partially discharged will take less time to reach their charged state. Batteries which have reached 80% of their charge capacity may be used, however, it is recommended that you allow the batteries to reach a full charge to maintain maximum battery life.