12. Troubleshooting guide

English

Case 1. Starting failure

CHECK

PROBABLE CAUSES

ACTION

fuel tank

incorrect fuel

fuel filter

fuel filter is clogged

carburetor adjustment screw

out of normal range

sparking (no spark)

spark plug is fouled/wet

 

plug gap is incorrect

spark plug

disconnected

drain it and with correct fuel

clean

adjust to normal range

clean/dry

correct (GAP: 0.6 – 0.7 mm)

retighten

Case 2. Engine starts but does not keep running/Hard re-starting.

CHECK

PROBABLE CAUSES

ACTION

fuel tank

incorrect fuel or staled fuel

carburetor adjustment screw

out of normal range

muffler,cylinder (exhaust port)

carbon is built-up

air cleaner

clogged with dust

cylinder fin, fan cover

clogged with dust

drain it and with correct fuel

adjust to normal range

wipe away

wash

clean

When your unit seems to need further service, please consult with our service shop in your area.

12. Guide de localisation des pannes

 

 

Français

 

 

 

 

 

 

1er cas : Défaut de démarrage

 

 

 

 

 

 

 

 

VERIFICATION

CAUSES PROBABLES

ACTION

réservoir de carburant

carburant incorrect

vidanger et remplacer le carburant

filtre à carburant

filtre à carburant colmaté

nettoyer

vis de réglage de carburateur

déréglé

refaire le réglage

allumage

bougie sale ou noyée

nettoyer ou sécher

 

Jeu d’électrodes incorrect

régler le jeu (de 0,6 à 0,7 mm)

Bougie d’allumage

débrancher

resserrer

 

2ème cas : Le moteur démarre mais ne reste pas en marche ou est difficile à redémarrer

 

 

 

 

 

VERIFICATION

 

CAUSES PROBABLES

 

ACTION

réservoir de carburant

carburant incorrect

vidanger et remplacer le carburant

vis de réglage de carburateur

déréglé

refaire le réglage

silencieux, cylindre

dépôt de calamine

retirer

filtre à air

colmaté de poussière

nettoyer

ailette de cylindre/flasque de ventilateur

colmaté de poussière

nettoyer

Si la machine nécessite des opérations d’entretien plus élaborées, contacter le centre de service après-vente le plus proche.

12. Guía de localización y solución de problemas

 

Español

 

 

 

 

Caso 1. El motor no arranca

 

 

 

 

 

 

COMPROBAR

POSIBLES CAUSAS

ACCIÓN

Tanque de combustible Filtro de combustible Tornillo de ajuste del carburador Explosión (no hay chispa)

Bujía

Combustible incorrecto

El filtro de combustible está obstruido.

Fuera del margen normal

La bujía está sucia/mojada.

La distancia interelectródica es incorrecta

Desconectada

Vaciar y llenar con el combustible correcto

Limpiar

Ajustar al margen normal

Limpiar/secar

Corregir (DISTANCIA INTERELECTRÓDICA: 0,6 – 0,7 mm)

Reajustarlo

Caso 2. El motor arranca pero no se mantiene en marcha./Dificultad para volver a arrancar el motor.

COMPROBAR

POSIBLES CAUSAS

ACCIÓN

Tanque de combustible

Combustible incorrecto

Tornillo de ajuste del carburador

Fuera del margen normal.

Silenciador, cilindro (lumbrera de escape)

Acumulación de carbón

Filtro de aire

Obstruido con polvo

Aletas del cilindro, cubierta de ventilador

Obstruidas con polvo

Vaciar y llenar con el combustible correcto.

Ajustar al margen normal.

Quitar

Lavar

Limpiar

Si le parece que la unidad necesita otros servicios, consulte nuestro centro de servicio en su área.

50

Page 50
Image 50
Zenoah RMSZ2601-CA, RMNBZ2601-CA manual Troubleshooting guide, Guide de localisation des pannes

RMSZ2601-CA, RMNBZ2601-CA, RMNBZ2601, RMSZ2601 specifications

The Zenoah RMSZ2601, RMNBZ2601, RMNBZ2601-CA, and RMSZ2601-CA are advanced, high-performance engines designed for professional use in various applications, particularly in the realms of landscaping, agriculture, and industrial equipment. Known for their reliability and durability, these engines are engineered to meet the rigorous demands of both commercial and residential users.

One of the standout features of these models is their two-stroke engine design, which allows for a higher power-to-weight ratio compared to four-stroke engines. This lightweight construction makes the Zenoah engines easier to maneuver and operate in tight spaces without sacrificing power. The RMSZ2601, for instance, boasts a displacement of 26 cc, delivering impressive torque and efficiency, making it suitable for a range of tasks from trimming to industrial drives.

Another key characteristic of these engines is their advanced ignition system, which enhances starting ease and operational stability. The incorporation of Zenoah’s unique digital ignition technology ensures a quick start and consistent performance across varying conditions. Additionally, these engines are equipped with an anti-vibration system that minimizes operator fatigue, enabling extended use without discomfort.

The RMNBZ2601 and its variants are also designed with an emphasis on reduced emissions. The CA models incorporate catalytic converters to meet stringent environmental regulations, making them a responsible choice for users conscious of their ecological footprint. This not only helps comply with governmental standards but also contributes to a cleaner working environment.

Moreover, Zenoah emphasizes user-friendly features in their engine designs. Both the RMSZ2601 and RMNBZ2601 models feature easy-access fuel and oil tanks that simplify refueling and maintenance. The filters are conveniently positioned for straightforward cleaning and replacement, ensuring longer operational life and reliability.

Durability is a hallmark of the Zenoah brand. The engines are constructed with high-grade materials that withstand the rigors of heavy-duty use. This ensures that the RMSZ2601, RMNBZ2601, and their variants maintain peak performance over time, even under challenging operating conditions.

In summary, the Zenoah RMSZ2601, RMNBZ2601, RMNBZ2601-CA, and RMSZ2601-CA represent cutting-edge technology in the small engine market, delivering robust performance, low emissions, and reliability. These features make them ideal choices for professionals in landscaping, agriculture, and other demanding sectors.