Installation - Ducting Options

www.zephyronline.com

Installation - Ducting Options

 WARNING FIRE HAZARD WARNING FIRE HAZARD

NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.

All exhaust must be ducted to the outside, unless using the recirculating op- tion.

Use single wall rigid Metal ductwork only.

Fasten all connections with sheet metal screws and tape all joints w/certified Silver Tape or Duct Tape.

Some Ducting Options