MOUNTING HEIGHTS

MOUNTING HEIGHTS

The range hood must be installed at a minimum height of 24 inches (61 cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood duct to the same duct used to exhaust hot air or fumes from another appliance. Before proceeding with the assembly instructions remove the decorative mesh filters so that the range hood is easier to handle.

C

X

Mounting the Range HoodX = C - (4,3-1/16" + 24" + B)MOUNTING TO THE CEILINGInstallation4,3 - 1/16"

24"

B

Mounting the Range Hood

X = C - (4,3-1/16" + 24" + B)

MOUNTING TO THE CEILING

-

The following instructions assume the installer has access to the attic or crawl space. Each installation may be unique to the home.

1.Remove the (2) screws to unlock the top support frame from the bottom support frame. Fig.9. Adjust the height by referring to the diagram in Fig. 8. Secure the support frames together with (2 type B) screws per extension arm (Tot. 8 type B). Fig.10

2.Place correct size ducting for your installation (not supplied) on top of hood and secure to the blower collar with aluminum duct tape. The ducting should be long enou- gh so it protrudes out the top of the support frame and extends