Min 34"-Max 52"

9"

Min 28"-Max 36"

Min 98"-Max 124”

36"

DUCTING

Aminimumof 6” round or 3-1 /4 x 10" rectangular duct work must be used to maintain maximumair flow efficiency with the 600 cfm internal blower. A minimumof 10” to 8” round must be used with the 1000 cfm external blower.

Always use rigid type metal duct work only. Flexible ducts could restrict air flow by up to 50%.

Use calculation worksheet to compute total duct work.

ALWAYS, when possible, reduce the number or transitions and turns. If a reducer is used, install a long reducer instead of a pancake reducer. Reduce duct size as far away from opening as possible.

If turns or transitions are required:

Install as far away from opening and as far apart, between 2, as possible.

Minimummount height between range top to hood bot- tom should be no less than 28".

Maximum mount height should be no higher than 36".

It is importantto install the hood at the proper mounting height. Hoods mountedtoo low could result in heat damage and fire hazard; while hoods mountedtoo high will be hard to reach and will loose its performance and efficiency.

If available, also refer to range manufacturer's height clearance requirements and recommended hood mountingheight above range. Always check your local codes for any differences.

*Minimum ceiling height of 98”. Hood mounted at 28” above cooking surface.

**Maximum ceiling height of 124". Hood mounted at 36" above cooking surface.

Minimum Duct Size:

Round - 6” minimumat 600 cfm Round - 10” to 8” minimum at 1000 cfm Rect angular - 3 1/4” x 10” minimum only if using internal blower at 600 cfm. Using rectangular ductwork will require a transition adapter (not provided, but readily available at most hardware stores).

DAMAGE-SHIPMENT/ INSTALLATION:

Please fully inspect unit for damage befor e installation.

If the unit is damaged in shipment , return the unit to the store in which it was bought for repair or replacement.

If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.

If the unit is damaged by the ins taller (if other than the customer), repair of replace ment must be made by arrangement between customer and installer.

Installation - Mounting Height & Clearance