Chapter 5 The Configuration Utility

Table 3 Configuration Screen (continued)

LABEL

DESCRIPTION

Site

This field displays

 

Local - This shows if PLA-407 is identifying the Powerline adapter

 

directly connected to the computer running the configuration utility.

 

Remote - This shows if PLA-407 is a Powerline adapter in your

 

Powerline network but not directly connected to the computer running

 

the configuration utility.

 

 

MAC Address

This is a read-only field which shows the MAC address of the Powerline

 

adapter you are configuring. You can find the MAC address of your PLA-

 

407 displayed on a sticker on the bottom of your device.

 

 

DAK

This shows the DAK (Device Access Key), which is the password used to

Password

verify that you are authorized to perform changes on a remote device. You

 

can find the DAK password printed on a sticker on the bottom of your PLA-

 

407.

 

 

Status

This shows Managed for ZyXEL Powerline devices that you can configure.

 

Otherwise, this shows Unmanaged for non-ZyXEL devices detected in the

 

Powerline network.

 

 

DAK

Select the remote Powerline adapter you want to manage by clicking the

Password

MAC address which corresponds to it in the MAC Address column. Enter

 

the DAK Password value and click Save.

 

Note: You must enter the DAK Password value exactly as it is printed

 

on the label (all caps and with dashes “-”).

 

 

Network

The default network name (sometimes called a network password or

Name (NMK)

network membership key (NMK)) of the PLA-407 is “HomePlugAV”.

 

HomePlug compatible devices use the same network name to recognize

 

and communicate with each other over the Powerline network. If you

 

change the network name of one device on the network, it will no longer

 

be recognized as part of that network.

 

If you change the network name, make sure you change the network

 

name for all of the Powerline adapters that you want to be part of your

 

Powerline network.

 

The network name can be from 8 to 64 characters in length, using

 

“A”~”Z”, “a”~”z”, “0”~”9”; spaces are not allowed.

 

 

Set NMK to

Select this to apply the NMK (entered in the field above) as the network

this device

name for the Powerline adapter directly connected to the computer

 

running the configuration utility.

 

 

Set NMK to

Select this to apply the NMK (entered in the field above) as the network

all managed

name for all Powerline adapter detected by the utility.

devices

 

 

 

Write

Click this to apply your changes. The new Network Name is applied to

 

the selected Powerline adapter.

 

Note: You must enter the correct DAK password for the selected

 

Powerline adapter before you can make changes to it.

40

 

PLA-407 User’s Guide