Lincoln Electric IM871-A manual Guards off

Page 49

Keep your head out of fumes.

Turn power off before servicing.

Do not operate with panel open or

WARNING

remove fumes from breathing zone.

 

guards off.

Use ventilation or exhaust to

 

 

 

 

 

 

Los humos fuera de la zona de res-

Desconectar el cable de ali-

No operar con panel abierto o

Spanish

piración.

mentación de poder de la máquina

guardas quitadas.

AVISO DE

Mantenga la cabeza fuera de los

antes de iniciar cualquier servicio.

 

aspiración para gases.

 

 

PRECAUCION

humos. Utilice ventilación o

 

 

 

 

 

 

 

Gardez la tête à l’écart des fumées.

Débranchez le courant avant l’entre-

N’opérez pas avec les panneaux

French

Utilisez un ventilateur ou un aspira-

tien.

ouverts ou avec les dispositifs de

ATTENTION

de travail.

 

protection enlevés.

teur pour ôter les fumées des zones

 

 

 

 

 

 

Vermeiden Sie das Einatmen von

Strom vor Wartungsarbeiten

Anlage nie ohne Schutzgehäuse

German

Schweibrauch!

abschalten! (Netzstrom völlig öff-

oder Innenschutzverkleidung in

WARNUNG

Sorgen Sie für gute Be- und

nen; Maschine anhalten!)

Betrieb setzen!

Entlüftung des Arbeitsplatzes!

 

 

 

 

 

 

Mantenha seu rosto da fumaça.

Não opere com as tampas removidas.

Mantenha-se afastado das partes

Portuguese

ATENÇÃO

Use ventilação e exhaustão para

Desligue a corrente antes de fazer

moventes.

remover fumo da zona respiratória.

serviço.

Não opere com os paineis abertos

 

Não toque as partes elétricas nuas.

ou guardas removidas.

 

 

 

 

 

 

 

 

Japanese

Chinese

Korean

Arabic

LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.

Image 49
Contents POWER-ARC California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté On-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Technical Specifications POWER-ARC InstallationLocation and Ventilation Safety PrecautionsStoring Engine Exhaust can killGasoline Fuel only PRE-OPERATION Engine ServiceMuffler Deflector PowerArc 5500 Typical Fuel ConsumptionSpark Arrester Honda 9 HPElectrical Output Connections POWER-ARC 5500 Output ConnectionsWelding Cable Connections Cable Size and LengthCable Installation Auxiliary Power ReceptaclesPlugs and HAND-HELD Equipment Machine GroundingCircuit Breakers Premises WiringType Common Electrical Devices Possible Concerns Table A.2 Electrical Device USE with the POWER-ARCOperation Limitations Controls and SettingsOutput Panel Controls Physical Location of Components may vary by Code NoGasoline Engine Controls Engine OperationStarting the Engine Before Starting the EngineStopping the Engine Generator OperationRunning the Engine BREAK-IN PeriodTable B.3 Generator Power Applications Control Function / Operation Current Control Dial Welding OperationWelding Guidelines Material Thickness Electrode Type Size SettingWelding arc What Happens in the Arc?Correct Way to Strike An Arc Correct Welding PositionCorrect Arc Length Correct Welding SpeedTypes of Welds Common MetalsUse the following Do the followingPenetration Fillet JointsMultiple Pass Welds Welding in the Vertical PositionVertical-Down Welding Vertical-Up WeldingOverhead Welding How to Hardface the Sharp Edge Metal to Ground WearWelding Sheet Metal Hardfacing To Reduce WearCast Iron Plate Preparation Welding Cast IronOut-of-Position Group AWS E6011 High-Speed Group AWS E6013 Selecting ElectrodesLow Hydrogen Group AWS E7018 OPTIONS/ACCESSORIES AccessoriesLincoln Electric Accessories Routine and Periodic Maintenance MaintenanceEngine Maintenance Figure D.3 Clean Rotating SCREEN/FINGER GUARD/DEBRIS Guard Engine AdjustmentsPart Robin / Subaru Honda Table D.1 Engine Maintenance PartsFigure D.5. Brush Removal and Replacement GENERATOR/WELDER MaintenanceFigure D.6. Major Component Locations HOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service Facility SymptomsTroubleshooting Engine requires service to head, head gasket, and/or valves Enhanced Diagram DiagramsDiagrams Diagrams Diagrams Power ARC Print Dimension Page Precaucion Guards off

IM871-A specifications

The Lincoln Electric IM871-A is a cutting-edge industrial welding machine that exemplifies the brand's commitment to quality, innovation, and efficiency. Designed specifically for professionals in various sectors, including manufacturing, construction, and maintenance, the IM871-A boasts a range of features that streamline the welding process while ensuring longevity and reliability.

One of the standout features of the IM871-A is its advanced inverter technology. This technology not only enhances the machine’s portability but also improves energy efficiency. The inverter design allows for a compact and lightweight unit without sacrificing power output, making it easier for welders to move around job sites while maintaining peak performance. Welders can expect to achieve high-quality welds with minimal spatter, ensuring a clean and professional finish.

The IM871-A is equipped with a multifunctional interface, allowing users to easily navigate through various settings and customize their welding parameters according to specific project requirements. This user-friendly display includes digital readouts for voltage and current, providing real-time information that aids in precision control. Such adaptability makes the IM871-A suitable for a wide range of welding applications, from thin sheet metal to heavier structural components.

Additionally, the Lincoln Electric IM871-A supports multiple welding processes, including MIG, TIG, and Stick welding. This versatility makes it an ideal choice for professionals who require a machine that can handle diverse tasks without the need for multiple setups or equipment. The welder's robust output range further enhances its capabilities, accommodating various materials and thicknesses for both ferrous and non-ferrous metals.

Safety is paramount in any welding operation, and the IM871-A incorporates several features designed to protect the user. These include built-in thermal overload protection, which prevents the machine from overheating during extended use, and an automatic voltage reduction system that ensures the welder remains safe while efficiently managing power.

In summary, the Lincoln Electric IM871-A is a powerful and versatile welding machine built to meet the rigorous demands of industrial applications. With its advanced inverter technology, intuitive user interface, multiple welding process support, and essential safety features, it stands out as a reliable choice for professionals aiming for quality and efficiency in their welding operations. Whether for onsite applications or workshop environments, the IM871-A is engineered to deliver exceptional performance and durability, solidifying its place in the competitive welding market.