Orbit Manufacturing 57922, 91916, 57916, p 801 295 9820, 57912, 57926, 94922 Connecting Sprinkler Wire

Page 15

To avoid electrical hazards, only one valve should be connected to each station.

IMPORTANT: The wire can be buried in the ground. However, for greater protection, wires can be pulled through PVC pipe and buried underground. Be careful to avoid burying the wires in locations where they could be damaged by future digging or trenching.

B.Connect Valve Wires to the Sprinkler Timer

Strip 1/4" (6 mm) of the plastic insulation off the end of each wire.

Determine which valve you want to connect to which station. Insert each sprinkler wire, excluding the “common” wire, into a separate station socket (num- bered above each socket) by inserting the bare wire fully into the socket under each number. (See Figure 5)

SENSOR

COM PUMP 1 2 3 4 5 6 7 8

9 10 11 12 24 VAC

 

Terminal Button

Common Wire

Station Valves

Figure 5: Connecting Sprinkler Wire

14

07WTM002598 57926-24 rA.indd 14

Connect the common wire to one of the two sockets (white in color) labeled “COM.”

NOTE: Insert only one wire into each “COM” socket. If more than two common wires are required, splice several together so only one wire runs into each of the two “COM” terminals. Protect the splice connection with a wire nut.

C. Connect Pump Start and Master Valve

This timer allows a master valve or pump start relay to oper- ate whenever a station is on.

NOTE: If you are activating a pump from this timer, you must purchase a Pump Start Relay.

From the pump start relay (or master valve); connect one wire to the “PUMP” socket and the other wire to the “COM” socket.

Once all connections to the docking port are made, you may slide the timer back onto the docking port.

5.Mount the Sleeve for the Remote Control Device

Using the mounting template (included) mark the two screw locations on the wall, then drill holes at the marks for No. 8 screws. Use the expanding anchors in plaster or masonry if necessary. (The sleeve can be mounted any where and does not need to be next to the timer.)

Place the remote control device sleeve against the wall, aligning the two holes in the sleeve with the two drilled holes.

2/16/07 2:07:25 PM

Image 15
Contents Page ST2-RF Sprinklertimer Manual Table of Contents Commonly Used Controls About This Manual Getting StartedSet the Time of Day and Date Reset the TimerActivating the Batteries Select the Preferred LanguageSet Station Watering Durations Programming Your TimerDetermine a Watering Plan Set Start TimesTo Prevent Watering on a Particular Day Set the Timer to Automatically Run Your ProgramsSet Watering Days To Turn All Watering OffSet Water Budgeting To Prevent Watering During a Particular Period of the DayTest All Stations Manual Watering All StationsManual Watering Program a Manual Advance During Watering Rain Delay FunctionManual Watering Program B Manual Watering Single Stations To Water One Station Using the Remote Control Device To Synchronize the Remote Control Device with the Timer To Water All StationsSelect a Location Using the Optional Rain-Freeze SensorInstalling the Sprinkler Timer Five Easy Steps Returns control back to the timerMount the Docking Port Do not slide the timer back onto the docking port yetTwo power leads from the transformer into each Wire the Electric ValvesMount the Sleeve for the Remote Control Device Connecting Sprinkler WireCorrecting the Fault Diagnostics Circuit BreakerSmart-ScanDiagnostic Fault Sensing Fault NotificationTerm Definition Glossary of TermsPlants Symptom Possible Causes of Problems Correction Trouble ShootingOrbit Irrigation Limited Six-Year Warranty HelpListings Seis ciclos de horas de inicio por programa Características y funciones importantesInstalación en interiores del temporizador del PC Programable Programas doblesControles comúnmente utilizados Esfera de selección Sobre este manualProgramación de los botones Reiniciación pequeño agujeroSección 2 Primeros pasos Activación de las bateríasSeleccione el idioma Ver Pág para las instrucciones Configure los horarios de comienzoColoque la hora del día y la fecha Determine un plan de riegoEstablezca los días de riego Configure para regar días imparesConfigure para regar días pares Coloque la duración del riego de la estaciónGire la esfera de selección a DÍA/PERÍODO SIN Riego Para desactivar todo el riegoPara impedir el riego en un día en particular Establezca el intervalo de riegoPresione el botón Ingresar . En el selector aparece Establezca el presupuesto de riegoPruebe todas las estaciones Riego manual Todas las estacionesAvanzar rápidamente de una estación a la siguiente presione Riego manual Programa aRiego manual Programa B Presione SiguienteColoque una batería en el dispositivo de control remoto Riego manual Estaciones individualesFunción de retardo por lluvia Avance manual durante el riegoPara regar todas las estaciones Para regar una estaciónPara regar más de una estación específica Elija el lugar Sección 5 Uso del sensor Lluvia-helada opcionalEn un área interna y seca, donde la temperatura de Monte la base de acoplamientoRealice el cableado de las válvulas eléctricas Conecte el transformadorVálvulas de Estación Monte el estuche para el control remotoCómo corregir la falla Sección 7 Interruptor de circuito con diagnósticoDetección y diagnóstico de fallas Smart-Scan Aviso de fallaTérmino Definición Sección 8 Glosario de términosDetermine un plan de riego Plantas Síntoma Posible causa del problema Corrección Sección 9 Solución de problemasClasificación Asistencia