Dynacord DSA 8209, DSA 8204, DSA 8206 Operating Voltage, Mains Switch, Mounting, Ventilation

Page 8

DIGITAL SYSTEM AMPLIFIER

2.2 Operating Voltage

The power amplifier receives its power supply via the MAINS IN connector. Only the provided power cord may be used. During installation, always separate the power amplifier from the mains. Connect the power amplifier only to a mains network, which corresponds to the requirements indicated on the type plate.

Mains Operation & Resulting Temperature

The power drawn from the mains network is converted into output power to feed the connected loudspeaker systems and into heat. The difference between power consumption and dispensed power is called power dissipation (Pd). The amount of heat resulting from power dissipation might remain inside of a rack-shelf and needs to be diverted using appropriate measures. The tables on page 31 allow the determination of power supply and cabling requirements. The tables are meant as auxiliary means for calculating temperatures inside of a rack-shelf system/cabinet and the ventilation efforts necessary.

The column Pd lists the leakage power in relation to different operational states. The column BTU/hr lists the dispensed heat amount per hour. Power consumption is direct proportional for other mains voltages. The following conversion factors are meant for easy conversion: 100V = 2.3; 120V = 1.9; 240V = 0.96

2.3 Mains Switch

The Mains Switch on the front panel separates the power amp from the mains. Turning the Mains Switch to ON starts booting up the power amp. A soft start circuit compensates mains inrush current peaks and thus prevents triggering AC mains fuse when switching on the amplifier. Speaker system switch-on is delayed by approximately 2 seconds via output relays, effectively suppressing any possible power-on noise, which otherwise might be heard through the loudspeakers. PROT-LED light and fans are at high speed during this delay. This indicates all protections are working fine.

2.4 Mounting

DSA amplifiers have been designed for installation in a conventional 19-inch rack case. Attach the power amp with its frontal rack mount ears using 4 screws and washers as shown in following illustration.

Additionally securing the amplifier at the rear becomes necessary, if the rack case in which the power amplifier has been installed will be transported. Failure to do so may result in damage to the power amplifier as well as to the rack case. Attach the power amp as shown in the illustration using 4 case nuts and screws. Brackets for securing the power amplifier are available as accessories.

2.5 Ventilation

As with all Dynacord power amps with fan cooling, the airflow direction is front-to- rear, obviously because there is more cold air outside of the rack case than inside.

The power amplifier remains cooler and dissipating the developing waste heat in a specific direction gets easier. In general, setting up or mounting the power amplifier has to be done in a way that fresh air can enter unhindered at the front

and exhausted air can exit at the rear. When installing the power amp in a case or rack system, attention should be paid to these details to provide sufficient

ventilation. Allow for an air duct of at least 60 mm x 330 mm between the rear

panel of the power amplifier and the inner wall of the cabinet/rack case. Make sure that the duct reaches up to the cabinet’s or the rack case’s top ventilation

louvers. Leave room of at least 100 mm above the cabinet/rack case for ventilation. Since temperatures inside of the cabinet/ rack case can easily rise up to 40 °C during operation of the power amp, it is mandatory to bear in mind the maximum allowable ambient temperature for all other appliances installed in the same cabinet/rack case.

8 Owner‘s Manual

Image 8
Contents Page Page Digital System Amplifier Important Safety Instructions Owner‘s ManualScope of Delivery and Warranty Features and DescriptionWelcome Unpacking and InspectionHF-Interference FCC Information USA Rear View Controls, Indicators and ConnectionsFront View Mains Switch Mains Operation & Resulting TemperatureOperating Voltage MountingHigh Pass Filter HPF Power on delayGroundlift Selecting the Mode Of Operation and Audio Output Cabeling DualAudio Input Cabeling Volume Control Indications30dB...LIMIT IRIS-NetStandby Mode Power Remote Fan CoolingControls and Connections System Description and FeaturesRCM-810 Data rate of the can bus is preset to 10 kbit/s Can addressesMaximally allowable current at the +5V output is 200 mA System Example Owner‘s ManualDigital System Amplifier Hinweise zur Entsorgung/Wiederverwendung gemäß Weee BedienungsanleitungWillkommen Auspacken und InspektionLieferumfang und Garantie Eigenschaften & BeschreibungRückseite Bedienelemente, Anzeigen und AnschlüsseFrontseite Betriebsspannung NetzschalterEinbau KühlungHochpassfilter HPF EinschaltverzögerungBetriebsart Mode und Verkabelung des Audio-Ausgangs Verkabelung des Audio-Eingangs Eingangspegel-Regler AnzeigenStandby-Modus Power Remote LüfterSystembeschreibung Bedienelemente und AnschlüsseDie Datenrate ist auf 10 kbit/s voreingestellt ADDRESS-WahlschalterDer maximale Strom am Ausgang +5V beträgt 200 mA CangndSpecifications/Technische Daten DSAMains Operation & Resulting Temperature Pout in W Pd in W1 BTU/hr2157 Block Diagram / Blockschaltbild Dimensions / Abmessungen Page Americas