Dynacord DSA 8204, DSA 8209, DSA 8206, DSA 8212 Groundlift, High Pass Filter HPF, Power on delay

Page 9

DIGITAL SYSTEM AMPLIFIER

CAUTION:

Blocking/closing the power amp’s ventilation louvers is not permissible. Without sufficient cooling/ventilation, the power amplifier may automatically enter protect mode. Keep ventilati- on louvers free from dust to ensure unhindered airflow.

Do not use the power amplifier near heat sources, like heater blowers, stoves or any other heat radiating devices.

To ensure trouble-free operation, make certain that the maximum allowable ambient tempera- ture of +40°C is not exceeded.

For fixed amplifier installations in a device control room that incorporate a central air-cooling system or air conditioners, calculating the maximum heat emission may be necessary. Please also take notice of the information on page 31.

2.6 Groundlift

The ground lift switch allows eliminating noise loops. When operating the power amplifier together with other equipment in a rack case, setting the switch to the GROUNDED position is recommended. Set the switch to UNGROUNDED, when the power amplifier is operated together with appliances with differing ground potentials.

2.7 High Pass Filter (HPF)

The Hi-Pass filter (50 Hz, 18 dB/oct) allows effective attenuation of low frequency audio signals, which could cause saturation problems with connected output transformers. Set the switch to the 50Hz position for activating the High Pass Filter. Set the switch to the OFF position if no attenuation of low frequency audio signals is required.

2.8 Power on delay

The ON DELAY switch at the amplifier rear panel allows selecting the power on delay time. Following table shows possible switch settings and corresponding delay times.

ON DELAY

Delay time

 

(in s)

 

 

0

0.52

 

 

1

0.59

 

 

2

0.63

 

 

3

0.69

 

 

4

0.75

 

 

5

0.84

 

 

6

0.90

 

 

7

0.95

 

 

ON DELAY

Delay time

 

(in s)

 

 

8

1.05

 

 

9

1.15

 

 

A

1.25

 

 

B

1.40

 

 

C

1.49

 

 

D

1.55

 

 

E

1.61

 

 

F

1.69

 

 

Owner‘s Manual 9

Image 9
Contents Page Page Digital System Amplifier Owner‘s Manual Important Safety InstructionsFeatures and Description Scope of Delivery and WarrantyWelcome Unpacking and InspectionHF-Interference FCC Information USA Controls, Indicators and Connections Front ViewRear View Mains Operation & Resulting Temperature Mains SwitchOperating Voltage MountingPower on delay GroundliftHigh Pass Filter HPF Dual Selecting the Mode Of Operation and Audio Output CabelingAudio Input Cabeling Indications Volume Control30dB...LIMIT IRIS-NetFan Cooling Standby Mode Power RemoteSystem Description and Features RCM-810Controls and Connections Can addresses Data rate of the can bus is preset to 10 kbit/sSystem Example Owner‘s Manual Maximally allowable current at the +5V output is 200 mADigital System Amplifier Bedienungsanleitung Hinweise zur Entsorgung/Wiederverwendung gemäß WeeeAuspacken und Inspektion WillkommenLieferumfang und Garantie Eigenschaften & BeschreibungBedienelemente, Anzeigen und Anschlüsse FrontseiteRückseite Netzschalter BetriebsspannungEinbau KühlungEinschaltverzögerung Hochpassfilter HPFBetriebsart Mode und Verkabelung des Audio-Ausgangs Verkabelung des Audio-Eingangs Anzeigen Eingangspegel-ReglerLüfter Standby-Modus Power RemoteBedienelemente und Anschlüsse SystembeschreibungADDRESS-Wahlschalter Die Datenrate ist auf 10 kbit/s voreingestelltCangnd Der maximale Strom am Ausgang +5V beträgt 200 mADSA Specifications/Technische DatenPout in W Pd in W1 BTU/hr2 Mains Operation & Resulting Temperature157 Block Diagram / Blockschaltbild Dimensions / Abmessungen Page Americas