DIGITAL SYSTEM AMPLIFIER
CAUTION:
Blocking/closing the power amp’s ventilation louvers is not permissible. Without sufficient cooling/ventilation, the power amplifier may automatically enter protect mode. Keep ventilati- on louvers free from dust to ensure unhindered airflow.
Do not use the power amplifier near heat sources, like heater blowers, stoves or any other heat radiating devices.
To ensure
For fixed amplifier installations in a device control room that incorporate a central
2.6 Groundlift
The ground lift switch allows eliminating noise loops. When operating the power amplifier together with other equipment in a rack case, setting the switch to the GROUNDED position is recommended. Set the switch to UNGROUNDED, when the power amplifier is operated together with appliances with differing ground potentials.
2.7 High Pass Filter (HPF)
The
2.8 Power on delay
The ON DELAY switch at the amplifier rear panel allows selecting the power on delay time. Following table shows possible switch settings and corresponding delay times.
ON DELAY | Delay time |
| (in s) |
|
|
0 | 0.52 |
|
|
1 | 0.59 |
|
|
2 | 0.63 |
|
|
3 | 0.69 |
|
|
4 | 0.75 |
|
|
5 | 0.84 |
|
|
6 | 0.90 |
|
|
7 | 0.95 |
|
|
ON DELAY | Delay time |
| (in s) |
|
|
8 | 1.05 |
|
|
9 | 1.15 |
|
|
A | 1.25 |
|
|
B | 1.40 |
|
|
C | 1.49 |
|
|
D | 1.55 |
|
|
E | 1.61 |
|
|
F | 1.69 |
|
|