Dynacord DSA 8805, DSA 8410, DSA 8405 Selecting the Mode of Output Output, Ohm Mode / VLD Mode

Page 10

DIGITAL SYSTEM AMPLIFIER

2.7 Selecting the Mode of Output (OUTPUT)

Different output modes are available for the amplifier‘s output channels. Each channel can be switched to high impedance mode (HZ) for driving 70 V or 100 V loudspeakers without output transformers (Direct Drive).

In DUAL or PARALLEL mode each output channel‘s OUTPUT setting can be independently set. In BRIDGED mode for each pair of outputs only the OUTPUT setting of the channel with odd number (1, 3, 5 or 7) matters, the OUTPUT setting of the channel with even number (2, 4, 6 or 8) is ignored.

Following section describes the four different OUTPUT settings of DSA amplifiers.

2 Ohm Mode / VLD Mode

In 2 Ohm mode the power amplifier reaches maximum output power having a load of 2 Ω connected. Up to 4 cabinetts having a nominal impedance of 8 Ω each can be driven by each amplifier channel. This mode should be used if a high number of speaker with medium or low power rating should be driven in low impedance mode (LZ). The VLD mode (Remote Control Module required) allows adjusting the output power of the amplifier channel. Please see page 11 for details about VLD mode.

Illustration 2.4: DUAL mode of CH 1 and CH 2 in 2 Ohm Mode

4 Ohm Mode

In 4 Ohm mode the power amplifier reaches maximum output power having a load of 4 Ω connected. Up to 2 cabinetts having a impedance of 8 Ω each can be driven by each amplifier channel. This mode should be used if speakers with high power rating (e.g. Subwoofers) should be driven in low impedance mode (LZ).

Illustration 2.5: DUAL mode of CH 1 and CH 2 in 4 Ohm Mode

10 Owner‘s Manual

Image 10
Contents Page Digital System Amplifier Important Safety Instructions Owner‘s ManualUnpacking and Inspection Scope of Delivery and WarrantyIntroduction Responsibility of the UserDigital System Amplifier Front View InstallationControls, Indicators and Connections Rear ViewOperating Voltage Mains SwitchMains Operation and Resulting Temperature MountingSelecting the Mode Of Operation Mode Fan CoolingMinimum load in Bridged mode Ohm Mode / VLD Mode Selecting the Mode of Output OutputOhm Mode Variable Load Drive VLD ModePower on delay Maximum Output Power VLD deactivatedAudio Cabling Output in Dual Mode or Parallel ModeOutput in Bridged Mode InputOperation Volume ControlStandby Mode Power Remote IndicationsOptions System Description and FeaturesRCM-810 Controls and Connections Illustration 4.1 Controls and Connections of the RCM-810Data rate of the can bus is preset to 10 kbit/s Maximally allowable current at the +5V output is 200 mABedienungsanleitung Wichtige Sicherheitshinweise Hinweise zur Entsorgung/Wiederverwendung gemäß WeeeLieferumfang und Garantie EinführungAuspacken und Überprüfen Verantwortung des BetreibersFrontseite Bedienelemente, Anzeigen und AnschlüsseRückseite Einbau BetriebsspannungNetzschalter KühlungWahl der Betriebsart Mode LüfterAbbildung 2.4 Betriebsart Bridged Ohm / VLD-Modus Wahl des Ausgangs-Modus OutputOhm-Modus Modus Einschaltverzögerung Ausgang in Betriebsart Dual bzw. Parallel Audio VerkabelungEingang Ausgang in Betriebsart Brückenbetrieb BridgedEingangspegel-Regler Standby-Modus Power RemoteBetrieb AnzeigenSystembeschreibung OptionenBedienelemente und Anschlüsse Tabelle 4.1 Werkseinstellungen RCM-810 Die Datenrate ist auf 10 kbit/s voreingestellt Der maximale Gesamtstrom am Ausgang +5V beträgt 200 mADSA Specifications/Technische DatenOwner‘s Manual / Bedienungsanleitung 1000 W5 500 W BTU/hr3 Mode Mains Operation & Resulting TemperatureDSA Output Alert Alarm Mode -3dB @ 4 Ω BTU/hrBlock Diagram / Blockschaltbild Dimensions / Abmessungen Digital System Amplifier