Dynacord DSA 8405, DSA 8410, DSA 8805 owner manual 500 W

Page 35

DIGITAL SYSTEM AMPLIFIER

DSA 8805

Amplifier at rated conditions, all channels driven, rated loads, unless otherwise specified.

Load Impedance

 

Low Impedance Mode

 

High Impedance Mode

2 Ω1

 

4 Ω2

 

8 Ω2

 

70 V / 10 Ω3

100 V / 20 Ω4

 

 

 

 

Maximum Midband Output Power

500 W5

 

500 W

 

250 W

 

500 W

500 W

THD = 1%, 1 kHz, 4 channels driven

 

 

VLD: 500 W

 

 

 

 

 

 

 

 

Rated Output Power

450 W

 

450 W

 

225 W

 

450 W

450 W

THD < 0.3%, 20 Hz6...20 kHz, 8 ch. driven

 

 

VLD: 450 W

 

 

 

 

 

 

 

 

Maximum Bridged Output Power

-

 

1000 W1

 

1000 W

 

1000 W7

1000 W8

THD= 1%, 1 kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum RMS Voltage Swing

32 V

 

45 V

 

45 V

 

70 V

100 V

THD = 1%, 1 kHz

 

 

VLD: 63 V

 

 

 

 

 

 

 

 

Power Bandwidth

 

 

10 Hz...25 kHz

 

50 Hz...25 kHz

THD = 1%, ref. 1 kHz, half power @ rated load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage Gain, ref. 1 kHz

32 dB

 

32 dB

 

32 dB

 

33 dB

36 dB

Input Sensitivity, rated power, 1 kHz

0.775 V

 

1.1 V

 

1.1 V

 

1.55 V

1.55 V

 

(+0.0 dBu)

 

(+3.0 dBu)

 

(+3.0 dBu)

 

(+6.0 dBu)

(+6.0 dBu)

THD at rated output power, MBW = 80 kHz, 1 kHz

 

 

 

< 0.05%

 

 

 

IMD-SMPTE, 60 Hz, 7 kHz

 

 

 

< 0.05%

 

 

 

DIM30, 3.15 kHz, 15 kHz

 

 

 

< 0.02%

 

 

 

Maximum Input Level

 

 

 

+22 dBu (9.76 Vrms)

 

 

Crosstalk, ref. 1 kHz, at rated output power

 

 

 

 

< -80 dB

 

 

Frequency Response, ref. 1 kHz, 8 Ω load

 

 

15 Hz6...30 kHz (±1 dB)

 

Input Impedance, active balanced

 

 

 

 

20 kΩ

 

 

Damping Factor, 1 kHz, 8 Ω

 

 

 

> 240

 

 

 

Slew Rate

 

 

 

 

28 V/μs

 

 

Signal to Noise Ratio Amplifier, A-weighted

98 dB

 

100 dB

 

100 dB

 

104 dB

106 dB

Output Noise, A-weighted

< -66 dBu

 

< -65 dBu

 

< -65 dBu

 

< -65 dBu

< -64 dBu

Output Stage Topology

 

 

 

 

Class D

 

 

Power Requirements (factory configured)

220-240 V, 50-60 Hz or 120 V, 50-60 Hz or 100 V9, 50-60 Hz

Power Consumption, 1/8 maximum output power

 

 

 

 

930 W

 

 

Protection

Audio Limiters, High Temperature, DC, HF, Short Circuit, Peak Current Limiters, Inrush

 

Current Limiters, Turn-on Delay, Mains Circuit Breaker Protection, Mains Over/Under-

 

 

 

 

voltage Protection

 

 

Cooling

 

 

Front-to-Rear, temperature controlled fans

 

Ambient Temperatur Limits

 

 

+5 °C...+40 °C (40 °F...105 °F)

 

Safety Class

 

 

 

 

I

 

 

Dimensions (W x H x D), mm

 

 

 

481 x 88.0 x 42110

 

 

Weight

 

 

 

13.9 kg (28.7 lbs)

 

 

Optional:

 

 

 

D113223 (RMK-15)

 

 

Rear-rackmount

 

 

 

 

 

1)Output Mode 2 Ω (500 W at 2 Ω, 250 W at 4 Ω, 125 W at 8 Ω)

2)Output Mode 4 Ω (500 W at 4 Ω, 250 W at 8 Ω)

3)Output Mode 70 V

4)Output Mode 100 V

5)Depending on the ambient temperature, the unit might reduce the output power at 2 Ω load

6)50 Hz High Pass is automatically activated in 70 V / 100 V output mode

7)140 V at 20 Ω

8)200 V at 40 Ω

9)Due to the mains voltage situation in Japan the values for the maximum output power can be decreased by 15%

10)Depth of the unit without rack ears (detachable): 380 mm

Owner‘s Manual / Bedienungsanleitung 35

Image 35
Contents Page Digital System Amplifier Owner‘s Manual Important Safety InstructionsResponsibility of the User Scope of Delivery and WarrantyIntroduction Unpacking and InspectionDigital System Amplifier Rear View InstallationControls, Indicators and Connections Front ViewMounting Mains SwitchMains Operation and Resulting Temperature Operating VoltageFan Cooling Selecting the Mode Of Operation ModeMinimum load in Bridged mode Ohm Mode Selecting the Mode of Output OutputOhm Mode / VLD Mode Mode Variable Load Drive VLDMaximum Output Power VLD deactivated Power on delayInput Output in Dual Mode or Parallel ModeOutput in Bridged Mode Audio CablingIndications Volume ControlStandby Mode Power Remote OperationRCM-810 System Description and FeaturesOptions Illustration 4.1 Controls and Connections of the RCM-810 Controls and ConnectionsMaximally allowable current at the +5V output is 200 mA Data rate of the can bus is preset to 10 kbit/sBedienungsanleitung Hinweise zur Entsorgung/Wiederverwendung gemäß Weee Wichtige SicherheitshinweiseVerantwortung des Betreibers EinführungAuspacken und Überprüfen Lieferumfang und GarantieRückseite Bedienelemente, Anzeigen und AnschlüsseFrontseite Kühlung BetriebsspannungNetzschalter EinbauLüfter Wahl der Betriebsart ModeAbbildung 2.4 Betriebsart Bridged Ohm-Modus Wahl des Ausgangs-Modus OutputOhm / VLD-Modus Modus Einschaltverzögerung Ausgang in Betriebsart Brückenbetrieb Bridged Audio VerkabelungEingang Ausgang in Betriebsart Dual bzw. ParallelAnzeigen Standby-Modus Power RemoteBetrieb Eingangspegel-ReglerBedienelemente und Anschlüsse OptionenSystembeschreibung Tabelle 4.1 Werkseinstellungen RCM-810 Der maximale Gesamtstrom am Ausgang +5V beträgt 200 mA Die Datenrate ist auf 10 kbit/s voreingestelltOwner‘s Manual / Bedienungsanleitung Specifications/Technische DatenDSA 1000 W5 500 W DSA Output Mains Operation & Resulting TemperatureBTU/hr3 Mode BTU/hr Alert Alarm Mode -3dB @ 4 ΩBlock Diagram / Blockschaltbild Dimensions / Abmessungen Digital System Amplifier