DIGITAL SYSTEM AMPLIFIER
not affected by VLD. Power amplifier channels behave as described in chapter 2.7. The use of VLD considerably expands the adaptability of a power amplifier. Table 2.4 lists some application examples of VLD.
| 2 Ω |
| 4 Ω | 8 Ω | |
125 W |
|
|
| 2 Ω Mode DSA 8x05 | |
|
|
|
|
| |
|
| 2 Ω Mode DSA 8x05 | 4 Ω Mode DSA 8x05 | ||
250 W |
| or | |||
|
|
|
| 2 Ω Mode DSA 8410 | |
|
|
|
| ||
500 W | 2 Ω Mode DSA 8x05 | 4 Ω Mode DSA 8x05 or | 4 Ω Mode DSA 8410 or | ||
2 | Ω Mode DSA 8410 | Bridge 2 Ω DSA 8x05 | |||
|
| ||||
|
|
|
| ||
1000 W | 2 Ω Mode DSA 8410 | 4 Ω Mode DSA 8410 or | Bridge 4 Ω DSA 8x05 or | ||
Bridge 2 Ω DSA 8x05 | Bridge 2 Ω DSA 8410 | ||||
|
| ||||
|
|
|
| ||
2000 W |
| Bridge 2 Ω DSA 8410 | Bridge 4 Ω DSA 8410 | ||
|
|
|
|
|
Table 2.3: Maximum Output Power (VLD deactivated)
| 2 Ω | 4 Ω | 8 Ω | |
125 W | VLD, all types | VLD, all types | 2 Ω Mode DSA 8x05 or | |
VLD DSA 8410 | ||||
|
|
| ||
|
|
|
| |
250 W | VLD, all types | 2 Ω Mode DSA 8x05 or | 4 Ω Mode DSA 8x05 or | |
VLD DSA 8410 | 2 Ω Mode DSA 8410 | |||
|
| |||
|
|
|
| |
| VLD DSA 8410 or | 4 Ω Mode DSA 8x05 or | VLD DSA 8x05 or | |
500 W | 4 Ω Mode DSA 8410 or | |||
2 Ω Mode DSA 8x05 | 2 Ω Mode DSA 8410 | |||
| Bridge 2 Ω DSA 8x05 | |||
|
|
| ||
|
|
|
| |
| 2 Ω Mode DSA 8410 | 4 Ω Mode DSA 8410 or | VLD DSA 8410 or | |
1000 W | Bridge 4 Ω DSA 8x05 or | |||
Bridge 2 Ω DSA 8x05 | ||||
|
| Bridge 2 Ω DSA 8410 | ||
|
|
| ||
|
|
|
| |
2000 W |
| Bridge 2 Ω DSA 8410 | Bridge 4 Ω DSA 8410 | |
|
|
|
|
Table 2.4: Maximum Output Power (VLD activated)
2.9 Power on delay
The ON DELAY switch on the amplifier rear panel allows selection of the power on delay time. Following table shows possible switch settings and corresponding delay times in seconds.
ON DELAY | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | A | B | C | D | E | F | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Delay time | 0 | 0.15 | 0.3 | 0.45 | 0.6 | 0.75 | 0.9 | 1.05 | 1.2 | 1.35 | 1.5 | 1.65 | 1.8 | 1.95 | 2.1 | 2.25 | |
(in s) | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION:
The setting of ON DELAY is ignored if a Remote Control Module is assembled.