DIGITAL SYSTEM AMPLIFIER

ventilation. Since temperatures inside of the cabinet/rack case can easily rise up to 40 °C during operation of the power amp, it is mandatory to bear in mind the maximum allowable ambient temperature for all other appliances installed in the same cabinet/rack case.

CAUTION:

Blocking/closing the power amp’s ventilation louvers is not permissible. Without sufficient cooling/ventilation, the power amplifier may automatically enter protect mode. Keep ventilati- on louvers free from dust to ensure unhindered airflow.

Do not use the power amplifier near heat sources, like heater blowers, stoves or any other heat radiating devices.

To ensure trouble-free operation, make certain that the maximum allowable ambient tempera- ture of +40°C is not exceeded.

For fixed amplifier installations in a device control room that incorporates a central air-cooling system or air conditioners, calculating the maximum heat emission may be necessary. Please also take notice of the information on page 7.

Fan Cooling

The power amplifier has two fans. The fans are temperature controlled, i.e. they are not running permanently but the running speed of the fans is controlled continuously depending on the ambient temperature. That in return ensures very silent running during idle state. The temperatures of the power amp‘s channels are registered and monitored separately.

2.6 Selecting the Mode Of Operation (MODE)

The MODE switch on the power amp‘s rear panel defines how the audio inputs handle the input signals. The amplifier types DSA 8405 and DSA 8410 allow the configuration of audio inputs CH 1/CH 2 or CH 3/CH 4, the amplifier type DSA 8805 additionally allows configuration of audio CH 5/CH 6 or CH 7/CH 8.

In the following description of the modes DUAL, PARALLEL or BRIDGED the generic letters A and B are used for the two audio inputs of a MODE switch (e.g. for switch CH 1/CH 2 input A corresponds to CH 1 and input B corresponds to CH 2).

DUAL

In DUAL mode, the two channels of the power amplifier work independent from each other. This mode of operation is being used for all 2-channel applications, like stereo or Bi-Amp (active) operation. Using the input level controls on the power amp’s rear panel allows independently adjusting the channels’ amplification.

Illustration 2.1: Audio signal applied to both input connectors in DUAL mode

8 Owner‘s Manual

Image 8
Contents Page Digital System Amplifier Important Safety Instructions Owner‘s ManualScope of Delivery and Warranty IntroductionUnpacking and Inspection Responsibility of the UserDigital System Amplifier Installation Controls, Indicators and ConnectionsFront View Rear ViewMains Switch Mains Operation and Resulting TemperatureOperating Voltage MountingSelecting the Mode Of Operation Mode Fan CoolingMinimum load in Bridged mode Ohm Mode Selecting the Mode of Output OutputOhm Mode / VLD Mode Variable Load Drive VLD ModePower on delay Maximum Output Power VLD deactivatedOutput in Dual Mode or Parallel Mode Output in Bridged ModeAudio Cabling InputVolume Control Standby Mode Power RemoteOperation IndicationsRCM-810 System Description and FeaturesOptions Controls and Connections Illustration 4.1 Controls and Connections of the RCM-810Data rate of the can bus is preset to 10 kbit/s Maximally allowable current at the +5V output is 200 mABedienungsanleitung Wichtige Sicherheitshinweise Hinweise zur Entsorgung/Wiederverwendung gemäß WeeeEinführung Auspacken und ÜberprüfenLieferumfang und Garantie Verantwortung des BetreibersRückseite Bedienelemente, Anzeigen und AnschlüsseFrontseite Betriebsspannung NetzschalterEinbau KühlungWahl der Betriebsart Mode LüfterAbbildung 2.4 Betriebsart Bridged Ohm-Modus Wahl des Ausgangs-Modus OutputOhm / VLD-Modus Modus Einschaltverzögerung Audio Verkabelung EingangAusgang in Betriebsart Dual bzw. Parallel Ausgang in Betriebsart Brückenbetrieb BridgedStandby-Modus Power Remote BetriebEingangspegel-Regler AnzeigenBedienelemente und Anschlüsse OptionenSystembeschreibung Tabelle 4.1 Werkseinstellungen RCM-810 Die Datenrate ist auf 10 kbit/s voreingestellt Der maximale Gesamtstrom am Ausgang +5V beträgt 200 mAOwner‘s Manual / Bedienungsanleitung Specifications/Technische DatenDSA 1000 W5 500 W DSA Output Mains Operation & Resulting TemperatureBTU/hr3 Mode Alert Alarm Mode -3dB @ 4 Ω BTU/hrBlock Diagram / Blockschaltbild Dimensions / Abmessungen Digital System Amplifier