Dynacord DPA 4260, DPA 4245 Eingänge INPUT CHANNEL A&B, Nachrüstanleitung Eingangsübertrager NRS

Page 5
Eingänge INPUT CHANNEL A&B

230V

50-60 Hz

CAUTION

 

 

 

 

 

 

 

 

 

 

 

 

870 WATTS

 

CHANNEL B

 

 

 

 

 

 

 

 

 

CHANNEL A

RISK OF ELECTRIC SHOCK

 

 

 

 

 

 

 

 

 

 

CIRCUIT T TO

DO NOT OPEN

 

INPUTS

 

 

 

 

INPUT

 

 

 

 

INPUTS

MAINS FUSE

 

POWER REMOTE

+

-9

-6

-5

-4-3

ROUTING

-9

-6

-5

-4-3

+

CHASSIS SWITCH

POWER

 

 

DUAL

 

 

T10A/L/250V

GROUNDED

+

 

-12

 

 

-2

 

-12

 

 

-2

 

 

 

 

-16

 

 

-1

 

-16

 

 

-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-30

 

 

 

-30

 

 

 

 

 

 

 

 

 

 

0 dB

 

 

 

0 dB

 

 

UNGROUNDED

 

 

 

 

 

 

 

 

 

 

 

 

SEE OPERATING MANUAL!

 

 

LEVEL

PARALLEL

LEVEL

 

 

 

 

 

 

CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE

 

WARNING: TO REDUCE THE RISK OF FIRE

REPLACE WITH SAME TYPE AND VALUE FUSE INDICATED.

 

OR ELECTRIC SHOCK, DO NOT EXPOSE THIS

ATTENTION:REMPLACER PAR UN FUSIBLE DE MEME TYPE

 

APPLIANCE TO RAIN OR MOISTURE.

COMME INDIQUE.

 

AVIS: RISQUE DE CHOC ELECTRIQUE. NE PAS OUVRIR.

AUDIO TRANSFORMER OUTPUTS

 

B

LOW IMPEDANCE

A

 

+ 100V

 

BRIDGED+

100V +

 

+ 25V +70V

 

1200W/8

 

70V+ 25V+

B

DUAL

A

 

 

 

 

+

600W

+

 

 

 

 

4

 

 

 

100 70

0 DIRECT OUTPUTS 0

70 100

OUTPUT WIRING MUST BE CLASS 1

 

ISOLATED OUTPUTS

 

 

 

 

+24V Nachrüstanleitung Eingangsübertrager NRS 90208 ON

0V Manual backgroundManual backgroundManual background OFF

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background DPA 4260 121715

NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

MADE IN GERMANY

BRIDGED MODE

Manual background NORMAL Manual background BRIDGED

S+

--

PIN 1: SHIELD

PIN 2: a, +

PIN 3: b, -

Manual backgroundManual backgroundManual background + Manual backgroundManual backgroundManual background

Eingänge INPUT CHANNEL A&B

Die Eingänge INPUT CHANNEL A&B sind elektronisch symmetrisch mit einer Eingangsempfindlichkeit von 775mV = 0 dBu für den Betrieb mit Steuerverstärkern, Audio Controllern, Mischpulten usw. ausgelegt. Die Eingangsimpedanz liegt bei 20kOhm symmetrisch.

Der Anschluß peripherer Geräte kann entweder über die XLR-Eingangs- buchsen oder die parallelgeschalteten Schraubsteckverbindungen, die im Lieferumfang enthalten sind, erfolgen. Das „Durchschleifen“ des Si- gnals zu weiteren Endstufen ist durch die direkte Parallelschaltung der beiden Anschlußvarianten ohne aufwendige Splitkabel möglich.

Die XLR-Eingangsbuchsen sind nach IEC Norm 268 beschaltet:

Stellt das Steuergerät keinen symmetrischen Ausgang zur Verfügung, können die Endstufeneingänge auch unsymmetrisch beschaltet werden. Dazu wird der Masse- bzw. Chassisanschluß (Pin1) mit dem - Eingang (Pin3) verbunden. Das Signal wird dann über den + Eingang (Pin2) eingespeist. Um jedoch die Vorteile der elektronisch symmetrischen Ein- gangsstufe, wie Brumm- und Störsignalunterdrückung im vollen Umfang zu nutzen, sollte sobald die Möglichkeit besteht auf die symmetrische Eingangsverdrahtung zurückgegriffen werden.Für den Fall, daß die Ein- gänge potentialfrei sein müssen, sind diese für die Nachrüstung von Ein- gangsübertrager vorgesehen. Es wird dazu je Kanal der Nachrüstsatz NRS 90208 (308840) benötigt.

Nachrüstanleitung Eingangsübertrager NRS 90208

Netzstecker ziehen

Alle Schrauben zur Haubenbefestigung entfernen

Öffnen des Gerätes durch Abnehmen der Abdeckhaube (Deckel)

Flachbandkabel an Printplatte 81340/1 abstecken

Schrauben zur Befestigung der Printplatte 81340/1 entfernen

Printplatte 81340/1 herausnehmen und die Widerstände R106 ... R109 auslöten.

Bestückung der Eingangsübertrager mit Isolierscheiben entsprechend Markierung auf der Printplatte.

Zusammenbau des Gerätes in umgekehrter Reihenfolge

5

Image 5
Contents Leistungsmerkmale DPA 4245 / DPA 4260 POWER AMPLIFIERBEDIENUNGSANLEITUNG OWNER‘S MANUAL MODE D‘EMPLOI WICHTIGE SICHERHEITSHINWEISE WICHTIGE SERVICEHINWEISEBESCHREIBUNG INHALTSVERZEICHNISBlock Diagramm BeschreibungInstallationshinweise Nachrüstanleitung Eingangsübertrager NRS Eingänge INPUT CHANNEL A&BLevel-Regler INPUT ROUTINGInput-Routing Leistungsausgänge A&BLeistungsausgänge Isolated Outputs 70V und Leistungsausgänge AUDIO TRANSFORMER OUTPUTSLeistungsausgänge DIRECT OUTPUTS Leistungsausgänge Isolated OutputsBridged Mode AUDIO TRANSFORMER OUTPUTSSignal-Anzeige Power On und FernsteuerungPower On Anzeige GROUND-LiftSchalterSchutzschaltungen Nachrüstsätze für DPA 4245 und DPA4260 Netzbetrieb und VerlustleistungSicherungen Technische Daten DPA 4245, DPA Brückenbetrieb DPA 4245 / DPA 4260 POWER AMPLIFIER FeaturesOWNER‘S MANUAL IMPORTANT SERVICE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONSDESCRIPTION CONTENTSBefore The First Operation Installation NotesInputs INPUT CHANNEL A&B Level Control Power Outputs A&BInput Routing INPUT ROUTINGPower Outputs - Isolated Outputs 70 V and Power Outputs - AUDIO TRANSFORMER OUTPUTSPower Outputs - DIRECT OUTPUTS Power Outputs - Isolated OutputsBridged Mode AUDIO TRANSFORMER OUTPUTSPower On And Remote Control GROUND Lift SwitchLimit Indicator Signal IndicatorProtection Circuitry Extension Kits For The DPA 4245 And The DPA Mains Operation And Leakage PowerFuses Technical Specifications DPA 4245, DPA 200V Caractéristiques DPA 4245 / DPA 4260 AMPLIFICATEUR DE PUISSANCEMODE D‘EMPLOI INSTRUCTIONS DE RÉPARATION IMPORTANTES INSTRUCTIONS DE SÉCURITÉ IMPORTANTESREMARQUE D‘ORIGINETABLE DES MATIERES DESCRIPTIONAvant la première utilisation Conseils d’installationL’amplificateur doit être protégé contre Entrées INPUT CHANNEL A&B Sélecteur d’assignation des entrées Potentiomètres de niveauPower Outputs A&B INPUT ROUTINGPage Sorties de puissance - Sorties isolées 25 Volts AUDIO TRANSFORMER OUTPUTS Mode Bridgé en pontIndicator ON Indicateur SignalCommutateur GROUND Lift Indicateur LimitCircuit de protection Kits d’extension pour le DPA 4245 et le DPA Consommation électrique et Puissance de fuiteFusibles Caractéristiques techniques DPA 4245, DPA apport Signal/BruitDPA4245 DPA4260MODE BRIDGÉ Dimensions L x H x PSortie directe Sorties isolée Sortie isoléePage 44,45 31,75 Abmessungen / Dimensions440,5 132,5Page Page Page Asia & Pacific Rim-HeadquarterAsia Bosch Communications SystemsAmericas-HeadquarterAmericas Europe, Africa & Middle-East
Related manuals
Manual 14 pages 18.24 Kb

DPA 4260, DPA 4245 specifications

Dynacord, a renowned name in professional audio equipment, has established a reputation for delivering high-performance amplifiers that meet the rigorous demands of live sound and installation applications. The DPA 4260 and DPA 4245 models stand out in their lineup, featuring advanced technologies and robust characteristics that set them apart in the competitive audio landscape.

The Dynacord DPA 4260 is a powerful four-channel amplifier that offers an impressive output of up to 2,600 watts, designed to drive a wide range of speakers effortlessly. One of its main features is the implementation of a sophisticated DSP (Digital Signal Processing) technology, which provides comprehensive control over audio parameters such as EQ, crossover, delay, and limiter settings. This allows users to optimize the sound output for various environments, ensuring clarity and fidelity in the audio performance.

In addition to DSP, the DPA 4260 is equipped with an advanced Power Factor Correction (PFC) system. This technology not only enhances the amplifier's efficiency but also ensures stable performance even under varying load conditions. The amplifier's robust build quality and efficient heat dissipation design make it suitable for extended operation in demanding venues.

On the other hand, the Dynacord DPA 4245 is another impressive model offering a slightly lower output of 1,400 watts but packed with its unique set of features. Like the DPA 4260, it benefits from the same DSP capabilities, allowing for detailed sound manipulation and tuning. This is particularly useful for sound engineers looking for precision in their audio setups.

The DPA 4245 also showcases versatility in its operation, featuring a selection of operating modes to accommodate different configurations, including bridge mode for driving larger loads. Its lightweight design makes it easy to transport and install without compromising on power or performance.

Both models come with comprehensive connectivity options, ensuring compatibility with various audio systems and setups, facilitating seamless integration into existing infrastructures. The front panel allows for easy monitoring, featuring LED indicators that display operational status and signal integrity.

In conclusion, Dynacord's DPA 4260 and DPA 4245 amplifiers exemplify cutting-edge technology and robust construction in the world of professional audio. With their powerful outputs, advanced DSP capabilities, and flexible configurations, these amplifiers are designed to meet the demands of professionals seeking reliable and high-quality audio solutions in live sound reinforcement and installation applications. Whether for touring, installations, or events, these amplifiers ensure a professional sound experience.