6.6Troubleshooting

The table below provides common symptoms of equipment troubles and the means to rectify them.

Symptom

 

Check, Remedy

Cannot turn on the

Check cable between transceiver unit and display unit.

power.

Check ship’s mains.

 

 

Have a suitably qualified technician check the fuse in the transceiver unit.

Bottom echo becomes

Rough seas. Distance to the bottom changes due to rolling and pitching.

irregular.

Long range selected. Transmission period is longer so ship’s pitching and

 

 

 

rolling are apt to affect detection of echo.

Weak echo

Output power set to minimum. Set to maximum, on the COM1 menu.

 

Excessive TVG. Readjust TVG on the appropriate menu (HORZ, VERT,

 

 

ES). Note that readjustment of TVG is necessary when gain is adjusted.

Somewhat strange

[BRILL] key setting too low. Increase brightness with [BRILL] key.

color

 

 

Picture contains noise.

Equipment not grounded properly. Check equipment ground.

 

Power cable is too close to the signal cable. Relocate power cable or

 

 

signal cable.

 

Debris may be on sea surface. Reject unwanted noise with the

 

 

interference rejector on the COM1 menu.

Picture does not

Problem in tilt mechanism or control line. Contact a FURUNO agent or

change when tilt angle

 

dealer for advice.

is changed. (Bottom is

 

 

not displayed in vertical

 

 

fan picture when

 

 

bottom is flat.)

 

 

6-4