2.4Selecting Sector Width

Sector means the width of the transducer training.

 

 

 

Display sector

 

 

 

96°

 

 

(shown: 96˚)

Figure 2-4 Display sector

The [SECTOR] control selects the training (display) area among the sixteen positions shown in the table below. Clockwise rotation of the control increases the sector width; counterclockwise rotation decreases it.

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Sector

6

24

48

72

96

120

144

168

192

216

240

264

288

312

336

360

width (° )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In the full-circle mode (360° ) the direction of training is clockwise; in the half-circle mode the direction is clockwise to counterclockwise alternately.

One-touch selection of 360° sector

Each pressing of the [FULL/HALF] key alternately selects 360° sector (full circle) or 168° sector (half circle). If the [SECTOR] control is operated following the selection of the full-circle display, the next pressing of the [FULL/HALF] key presents the full-circle display.

Sector set with

Full circle

Half circle

SECTOR control

 

FULL/HALF

FULL/HALF

 

key

 

key

168°

Figure 2-5 How the FULL/HALF key works

2-4

Page 22
Image 22
Furuno CH-250 manual Selecting Sector Width, One-touch selection of 360 sector